LM, light curtain muting
411
02/16 MN05013001Z EN
Wiring of the function block
Wire its coils I1 and I2, A1 and A2, as well as B1 and B2
directly to the device terminals IS1 to IS14. Example of an LM
function block:
Figure 209:
easySafety circuit diagram with light curtain
muting function block.
You can associate the function block contacts QM and QS
directly with one or several safety device outputs, for
example:
L
Figure 210:
Wiring the enable contact to two device outputs.
IS01---------------------------
Ä
LM01I1
IS02---------------------------
Ä
LM01I2
IS03---------------------------
Ä
LM01A1
IS04---------------------------
Ä
LM01A2
IS05---------------------------
Ä
LM01B1
IS06---------------------------
Ä
LM01B2
IS07---------------------------
Ä
LM01OV
LM01QM---------------------------
Ä
QS1
LM01QS--------------------------
uÄ
QS2
hÄ
QS3