BV, Boolean operation
211
02/16 MN05013001Z EN
Parameters
When using the function block in the circuit diagram for the
first time, use OK to automatically enter the general display
of function block parameters, as shown in the figure on the
left. Enter the function block settings here. The display
contains the following elements:
The parameters consist of the following:
Operating mode
This parameter is used to set the type of operation required.
The factory setting of this parameter is AND.
BV01 AND +
>I1
>I2
QV>
BV01
Function block: Boolean operation, number 01
AND
Mode: AND
+
Parameter display: Call enabled
>I1
First value
>I2
Second value
QV>
Result of the association
Parameters
Function
AND
AND operation
OR
OR operation
XOR
Exclusive OR operation
NOT
Negation of the Boolean value of >I1