![Eaton easySafety Manual Download Page 134](http://html1.mh-extra.com/html/eaton/easysafety/easysafety_manual_3958374134.webp)
Wiring with ea
s
ySafety
130
02/16 MN05013001Z EN
time a easySafety configuration is saved with a modified
safety configuration easySoft-Safety increases the version
number by 1.
If there is a transfer problem, the easySafety device shows
the CONFIG. INVALID message.
X
Check whether the device version in the configuration
matches the easySafety device used or whether the
memory card is not empty.
X
After transmission, remove the cable and close the cover.
h
In order to identify modifications to the safety
configuration that were carried out on the device, the
version number is always reset to 0000.
CONFIG. INVALID
h
If the operating voltage fails during communication with
the PC, repeat the last step. Not all data may have been
transferred between the PC and easySafety device.