BC, data block comparator
187
02/16 MN05013001Z EN
Wiring of the function block
You wire the function block in the standard circuit diagram
with its enable coil and its contacts. Example of a function
block for comparing data blocks:
Figure 76:
Wiring the enable coil
Figure 77:
Wiring the contacts
Parameters
When using the function block in the circuit diagram for the
first time, use OK to automatically enter the general display
of function block parameters, as shown in the figure on the
left. Enter the function block settings here. The display
contains the following elements:
The parameters consist of the following:
IS05--------------------------
Ä
BC11EN
BC11E1
o
BC11E2
s
BC11E3
j
-----------------------
Ä
M 48
BC11EQ-BC11EN-----------------
Ä
M 49
BC11 +
>I1
>I2
>NO
BC11
Function block: Data block comparator, number 11
+
Parameter display: Call enabled
>I1
Start of comparison range 1
>I2
Start of comparison range 2
>NO
Number of elements to be compared in bytes per range
Summary of Contents for easySafety