![Eaton easySafety Manual Download Page 218](http://html1.mh-extra.com/html/eaton/easysafety/easysafety_manual_3958374218.webp)
Standard function blocks
214
02/16 MN05013001Z EN
XOR Boolean operation
NOT Boolean operation
The NOT sequence operates according to the following rules:
>I1, positive value
Subtract value of >I1 and 1:
–|>I1| – 1 = >I2
>I1, negative value
Subtract value of >I1 and 1:
–|>I1| – 1 = >I2
Value >I1:
13219
dez
= 0011001110100011
bin
Value >I2:
57193
dez
= 1101111101101001
bin
Result QV>:
60618
dez
= 1110110011001010
bin
Value >I1:
13219
dez
=
00000000000000000011001110100011
bin
Value >I2:
deleted
Result QV>: -13220
dez
=
11111111111111111100110001011100
bin