4.3.14.10.6.3 ADC system status 2
Name:
SysStatus2
Data type
Value
UINT
See bit structure
Bit structure:
Bit
Name
Value
Information
0
No change of direction
0
RevPchgC, the direction of the active energy for phase C has
changed
1
Direction has changed
0
No change of direction
1
RevPchgB, the direction of the active energy for phase B has
changed
1
Direction has changed
0
No change of direction
2
RevPchgA, the direction of the active energy for phase A has
changed
1
Direction has changed
0
No change of direction
3
RevPchgT, the direction of the active energy for the total has
changed
1
Direction has changed
0
No change of direction
4
RevQchgC, the direction of the reactive energy for phase C has
changed
1
Direction has changed
0
No change of direction
5
RevQchgB, the direction of the reactive energy for phase B has
changed
1
Direction has changed
0
No change of direction
6
RevQchgA, the direction of the reactive energy for phase A has
changed
1
Direction has changed
0
No change of direction
7
RevQchgT, the direction of the reactive energy for the total has
changed
1
Direction has changed
8
Reserved
0
0
DFT analysis not complete
9
DFTDone, DFT analysis complete (temporary bit)
1
DFT analysis complete
0
THDIx value within permitted range
10
SumStatusWarningTHDCurrent, the THDIx value of one or more
phases > warning threshold in the register
1
THDIx value higher than warning threshold
0
THDUx value within permitted range
11
SumStatusWarningTHDVoltage, the THDUx value of one or
more phases > warning threshold in the register
1
THDUx value higher than warning threshold
12 - 13
Reserved
0
0
Calculated value within permitted range
14
ErrIrmsNCalc, the calculated value of the neutral line > warning
threshold in the Register
1
Calculated value higher than warning threshold
0
Measured value within permitted range
15
ErrIrmsNMeas, the measured value of the neutral line > warning
threshold in the Register
1
Measured value higher than warning threshold
4.3.14.10.6.4 ADC system status 3
Name:
SysStatus3
Data type
Value
UINT
See bit structure
Bit structure:
Bit
Name
Value
Information
0
Forward
1)
0
CF1RevFlag, direction of CF signal
1
Back
2)
0
Forward
1)
1
CF2RevFlag, direction of CF signal
1
Back
2)
0
Forward
1)
2
CF3RevFlag, direction of CF signal
1
Back
2)
0
Forward
1)
3
CF4RevFlag, direction of CF signal
1
Back
2)
4 - 11
Reserved
0
0
Status with load
12
TVSNoload, vector-based total apparent power of all phases in
"No load" state
1
Status without load
0
Status with load
13
TASNoload, total apparent power of all phases in "No load" state
1
Status without load
0
Status with load
14
TPNoload, total active power of all phases in "No load" state
1
Status without load
0
Status with load
15
TQNoload, total reactive power of all phases in "No load" state
1
Status without load
1)
Forward direction of CF pulse (positive sign of corresponding energy register)
2)
Reverse direction of CF pulse (negative sign of corresponding energy register)
Summary of Contents for X20 System