X20 system modules • Counter modules • X20DC2190
790
X20 system User's Manual 3.10
4.11.13.7.13 Offset position on the transducer
Name:
ConfigOutput07 to ConfigOutput08
ConfigOutput15 to ConfigOutput16
These registers are used to assign the respective magnet an offset position (= zero position) on the transducer.
The max. and min. magnet paths refer to these specified offsets (see 4.11.13.7.14 "Plausibility check configuration"
on page 790). If the offset is changed using the StatusOutput01 register, this becomes the new zero position.
This does not affect the contents of the offset register.
•
Offset magnet 1: ConfigOutput07
•
Offset magnet 2: ConfigOutput08
•
Offset magnet 3: ConfigOutput15
•
Offset magnet 4: ConfigOutput16
Data type
Value
DINT
-2,147,483,648 to 2,147,483,647: Resolution 1 µm
4.11.13.7.14 Plausibility check configuration
These registers are used to configure the plausibility check (also see section 4.11.13.7.6 "Error status" on page
4.11.13.7.14.1 Min. plausible magnet position
Name:
ConfigOutput09 to ConfigOutput10
ConfigOutput17 to ConfigOutput18
These registers are used to assign the min. plausible magnet position based on the applicable offset.
•
Min. path - magnet 1: ConfigOutput09
•
Min. path - magnet 2: ConfigOutput10
•
Min. path - magnet 3: ConfigOutput17
•
Min. path - magnet 4: ConfigOutput18
Data type
Value
DINT
-2,147,483,648 to 2,147,483,647: Resolution 1 µm
4.11.13.7.14.2 Max. plausible magnet position
Name:
ConfigOutput11 to ConfigOutput12
ConfigOutput19 to ConfigOutput20
These registers are used to assign the max. plausible magnet position based on the applicable offset.
•
Max. path - magnet 1: ConfigOutput11
•
Max. path - magnet 2: ConfigOutput12
•
Max. path - magnet 3: ConfigOutput19
•
Max. path - magnet 4: ConfigOutput20
Data type
Value
DINT
-2,147,483,648 to 2,147,483,647: Resolution 1 µm