X20 system modules • Analog input modules • X20AI1744, X20AI1744-3
X20 system User's Manual 3.10
129
4.3.2 X20AI1744, X20AI1744-3
4.3.2.1 General Information
The X20AI1744 and X20AI1744-3 modules work with both 4-line and 6-line strain gauge cells. If a 6-line strain
gauge cell is connected, the line compensation no longer functions. This module concept requires compensation
in the measurement system. This compensation eliminates the absolute uncertainty in the measurement circuit,
suchas component tolerances, effective bridge voltage, or zero offset. The measurement precision refers to the
absolute (compensated) value, which will only change as a result of changes in the operating temperature.
The AI1744 analog input module is available in two versions:
Model number
Description
X20AI1744
The module is equipped with a 5kHz input filter for fast signal sequences. It therefore also allows high frequency signals and
disturbances to pass through.
X20AI1744-3
This version is equipped with a slow 5Hz input filter. It is therefore suitable for slow signal sequences and provides good suppres-
sion of high frequency disturbance signals.
•
1 full-bridge strain gauge input
•
Data output rate can be set from 2.5 Hz to 7.5 kHz
•
Special operating modes (synchronous mode and multiple sampling)
4.3.2.2 Order data
Model number
Short description
Figure
Analog input modules
X20AI1744
X20 analog input module, 1 full-bridge strain gauge input, 24-bit
converter resolution, 5 kHz input filter
X20AI1744-3
X20 analog input module, 1 full-bridge strain gauge input, 24-bit
converter resolution, 5 Hz input filter
Required accessories
Bus modules
X20BM11
Bus module, 24 VDC keyed, internal I/O supply continuous
Terminal blocks
X20TB12
X20 terminal block, 12-pin, 24 VDC keyed
Table 18: X20AI1744, X20AI1744-3 - Order data
4.3.2.3 Technical data
Product ID
X20AI1744
X20AI1744-3
Short description
I/O module
1 full-bridge strain gauge input
General information
B&R ID code
0x1CDE
0xA4EF
Status indicators
Channel status, operating status, module status
Diagnostics
Module run/error
Yes, using status LED and software
Open line
Yes, using status LED and software
Input
Yes, using status LED and software
Power consumption
Bus
0.01 W
Internal I/O
1.25 W
Additional power dissipation caused by the actua-
tors (resistive) [W]
Max. 0.36 W
1)
Electrical isolation
Bus - Analog input
Yes
Bus - Bridge supply voltage
Yes
Channel - I/O supply
No
Certification
CE
Yes
cULus
Yes
KC
Yes
GOST-R
Yes
Full-bridge strain gauge
Strain gauge factor
±2 to ±256 mV/V, configurable using software
Table 19: X20AI1744, X20AI1744-3 - Technical data