X20 system modules • Other functions • X20CM4810
2172
X20 system User's Manual 3.10
4.26.2.5.6.18 OverflowAnalogInput01-04
Information:
This is always based on a 100 mV/g sensor.
This register is only available in Function model 0 - Standard.
4.26.2.5.6.19 OverflowCharacteristicValues01-04
This register contains an overflow indicator bit for each characteristic value of the respective channel (1 = Overflow).
Bit
Description
15
Reserved (always 0)
14
RmsRaw overflow
13
Iso10816 overflow
12
Vdi3832KtRaw overflow
11
KurtosisRaw overflow
10
SkewnessRaw overflow
9
CrestFactorRaw overflow
8
PeakRaw overflow
7
RmsVelRaw overflow
6
RmsAccRaw overflow
5
RmsVelEnvelope overflow
4
RmsAccEnvelope overflow
3
Vdi3832KtHighFrequency overflow
2
CrestFactorHighFrequency overflow
1
RmsHighFrequency overflow
0
PeakHighFrequency overflow
Table 761: OverflowCharacteristicsValues01-04
This register is only available in Function model 0 - Standard.
4.26.2.5.6.20 OverflowFrequencyBands01
This register contains an overflow indicator bit for each frequency band (1 = overflow).
Bit
Description
31
FrequencyBand32 overflow
...
...
0
FrequencyBand01 overflow
Table 762: OverflowFrequencyBands01
This register is only available in Function model 0 - Standard.
4.26.2.5.6.21 PeakHighFrequencyRef01-04
Reference (correct state) of the high frequency signal's peak value for calculating the Vdi3832 K(t) of the high
frequency signal.
This register is only available in Function model 0 - Standard.
4.26.2.5.6.22 PeakHighFrequencyRefCalculated01-04
Reference (correct state) of the high frequency signal's peak value that was used to calculate the Vdi3832 K(t)
of the peak value.
This register is only available in Function model 0 - Standard.
4.26.2.5.6.23 PeakRawRef01-04
Reference (correct state) of the raw signal's peak value used to calculate the Vdi3832 K(t) of the raw signal.
This register is only available in Function model 0 - Standard.
4.26.2.5.6.24 PeakRawRefCalculated01-04
Reference (correct state) of the raw signal's peak value that was used to calculate the Vdi3832 K(t) of the raw signal.
This register is only available in Function model 0 - Standard.