8.13.4 ADC Start of Conversion Priority Control Register (SOCPRICTL)
Figure 8-25. ADC Start of Conversion Priority Control Register (SOCPRICTL)
15
14
11
10
5
4
0
ONESHOT
Reserved
RRPOINTER
SOCPRIORITY
R/W-0
R-0
R-20h
R/W-0
LEGEND: R/W = Read/Write; R = Read only; -
n
= value after reset
Table 8-12. SOCPRICTL Register Field Descriptions
Bit
Field
Value
15
ONESHOT
0
One shot mode disabled
1
One shot mode enabled
14-11
Reserved
Reads return a zero; Writes have no effect.
10-5
RRPOINTER
Round Robin Pointer. Holds the value of the last converted round robin SOCx to be used by the
round robin scheme to determine order of conversions.
00h
SOC0 was last round robin SOC to convert. SOC1 is highest round robin priority.
01h
SOC1 was last round robin SOC to convert. SOC2 is highest round robin priority.
02h
SOC2 was last round robin SOC to convert. SOC3 is highest round robin priority.
03h
SOC3 was last round robin SOC to convert. SOC4 is highest round robin priority.
04h
SOC4 was last round robin SOC to convert. SOC5 is highest round robin priority.
05h
SOC5 was last round robin SOC to convert. SOC6 is highest round robin priority.
06h
SOC6 was last round robin SOC to convert. SOC7 is highest round robin priority.
07h
SOC7 was last round robin SOC to convert. SOC8 is highest round robin priority.
08h
SOC8 was last round robin SOC to convert. SOC9 is highest round robin priority.
09h
SOC9 was last round robin SOC to convert. SOC10 is highest round robin priority.
0Ah
SOC10 was last round robin SOC to convert. SOC11 is highest round robin priority.
0Bh
SOC11 was last round robin SOC to convert. SOC12 is highest round robin priority.
0Ch
SOC12 was last round robin SOC to convert. SOC13 is highest round robin priority.
0Dh
SOC13 was last round robin SOC to convert. SOC14 is highest round robin priority.
0Eh
SOC14 was last round robin SOC to convert. SOC15 is highest round robin priority.
0Fh
SOC15 was last round robin SOC to convert. SOC0 is highest round robin priority.
1xh
Invalid value
20h
Reset value to indicate no SOC has been converted. SOC0 is highest round robin priority. Set
to this value when the device is reset, when the ADCCTL1.RESET bit is set, or when the
SOCPRICTL register is written. In the latter case, if a conversion is currently in progress, it will
complete and then the new priority will take effect.
Others Invalid selection.