13.14.2.8 SCI Receive Data Buffer (SCIRXBUF) Register (Offset = 7h) [reset = 0h]
When the current data received is shifted from RXSHF to the receiver buffer, flag bit RXRDY is set and the
data is ready to be read. If the RXBKINTENA bit (SCICTL2.1) is set, this shift also causes an interrupt. When
SCIRXBUF is read, the RXRDY flag is reset. SCIRXBUF is cleared by a system reset.
Figure 13-18. SCI Receive Data Buffer (SCIRXBUF) Register
15
14
13
12
11
10
9
8
SCIFFFE
SCIFFPE
RESERVED
R-0h
R-0h
R-0h
7
6
5
4
3
2
1
0
SAR
R-0h
Table 13-15. SCI Receive Data Buffer (SCIRXBUF) Register Field Descriptions
Bit
Field
Type
Reset
Description
15
SCIFFFE
R
0h
SCIFFFE. SCI FIFO Framing error flag bit (applicable only if the
FIFO is enabled)
Reset type: SYSRSn
0h (R/W) = No frame error occurred while receiving the character, in
bits 7-0. This bit is associated with the character on the top of the
FIFO.
1h (R/W) = A frame error occurred while receiving the character in
bits 7-0. This bit is associated with the character on the top of the
FIFO.
14
SCIFFPE
R
0h
SCIFFPE. SCI FIFO parity error flag bit (applicable only if the FIFO is
enabled)
Reset type: SYSRSn
0h (R/W) = No parity error occurred while receiving the character, in
bits 7-0. This bit is associated with the character on the top of the
FIFO.
1h (R/W) = A parity error occurred while receiving the character in
bits 7-0. This bit is associated with the character on the top of the
FIFO.
13-8
RESERVED
R
0h
Reserved
7-0
SAR
R
0h
Receive Character bits
Reset type: SYSRSn
Serial Communications Interface (SCI)