If the application demands HRPWM operation in the low percent duty cycle region, then the HRPWM can be
configured to operate in count-down mode with the rising edge position (REP) controlled by the MEP when
high-resolution period is disabled (HRPCTL[HRPE] = 0). This is illustrated in
. In this case, low percent
duty limitation is no longer an issue. However, there will be a maximum duty limitation with same percent
numbers as given in
.
T
pwm
EPWM1A
0
TBPRD
3
SYSCLKOUT
Figure 4-8. High % Duty Cycle Range Limitation Example (HRPCTL[HRPE] = 0)
T
pwm
EPWM1A
0
TBPRD
3
SYSCLKOUT=
TBCLK
TBPRD - 3
Figure 4-9. Up-Count Duty Cycle Range Limitation Example (HRPCTL[HRPE]=1)