6.4.1 Event Prescaler
An input capture signal (pulse train) can be prescaled by N = 2-62 (in multiples of 2) or can bypass the prescaler.
This is useful when very high frequency signals are used as inputs.
shows a functional diagram and
shows the operation of the prescale function.
0
1
/n
5
ECCTL1[EVTPS]
prescaler [5 bits]
(counter)
By−pass
Event prescaler
ECAPx pin
(from GPIO)
PSout
A.
When a prescale value of 1 is chosen (ECCTL1[13:9] = 0,0,0,0,0), the input capture signal bypasses the prescale logic completely.
B.
The first Rise edge after Prescale configuration change is not passed to Capture logic, prescaler value takes into effect on the second
rising edge after the configuration.
Figure 6-5. Event Prescale Control
ECAPx
PSout
div 2
PSout
div 4
PSout
div 6
PSout
div 8
PSout
div 10
Figure 6-6. Prescale Function Waveforms
Enhanced Capture (eCAP)
SPRUH18I – JANUARY 2011 – REVISED JUNE 2022
TMS320x2806x Microcontrollers
435
Copyright © 2022 Texas Instruments Incorporated