Table 3-21. Time-Base Control Register (TBCTL) Field Descriptions (continued)
Bit
Field
Value
Description
9-7
HSPCLKDIV
High Speed Time-base Clock Prescale Bits
These bits determine part of the time-base clock prescale value.
TBCLK = SYSCLKOUT / (HSPCLKDIV × CLKDIV)
This divisor emulates the HSPCLK in the TMS320x281x system as used on the Event Manager
(EV) peripheral.
000
/1
001
/2 (default on reset)
010
/4
011
/6
100
/8
101
/10
110
/12
111
/14
6
SWFSYNC
Software Forced Synchronization Pulse
0
Writing a 0 has no effect and reads always return a 0.
1
Writing a 1 forces a one-time synchronization pulse to be generated.
This event is ORed with the EPWMxSYNCI input of the ePWM module.
SWFSYNC is valid (operates) only when EPWMxSYNCI is selected by SYNCOSEL = 00.
5-4
SYNCOSEL
Synchronization Output Select. These bits select the source of the EPWMxSYNCO signal.
00
EPWMxSYNC:
01
CTR = zero: Time-base counter equal to zero (TBCTR = 0x0000)
10
CTR = CMPB : Time-base counter equal to counter-compare B (TBCTR = CMPB)
11
Disable EPWMxSYNCO signal
3
PRDLD
Active Period Register Load From Shadow Register Select
0
The period register (TBPRD) is loaded from its shadow register when the time-base counter,
TBCTR, is equal to zero.
A write or read to the TBPRD register accesses the shadow register.
1
Load the TBPRD register immediately without using a shadow register.
A write or read to the TBPRD register directly accesses the active register.
2
PHSEN
Counter Register Load From Phase Register Enable
0
Do not load the time-base counter (TBCTR) from the time-base phase register (TBPHS)
1
Load the time-base counter with the phase register when an EPWMxSYNCI input signal occurs or
when a software synchronization is forced by the SWFSYNC bit, or when a digital compare sync
event occurs.
1-0
CTRMODE
Counter Mode
The time-base counter mode is normally configured once and not changed during normal
operation. If you change the mode of the counter, the change will take effect at the next TBCLK
edge and the current counter value shall increment or decrement from the value before the mode
change.
These bits set the time-base counter mode of operation as follows:
00
Up-count mode
01
Down-count mode
10
Up-down-count mode
11
Stop-freeze counter operation (default on reset)
Enhanced Pulse Width Modulator (ePWM) Module
SPRUH18I – JANUARY 2011 – REVISED JUNE 2022
TMS320x2806x Microcontrollers
329