Table 1-22. Clock Control (CLKCTL) Register Field Descriptions (continued)
Bit
Field
Value
Description
9
INTOSC1HALTI
Internal Oscillator 1 HALT Mode Ignore bit. This bit selects if the internal oscillator 1 is
automatically turned off by the HALT mode or not:
0
Internal oscillator 1 automatically turned Off by HALT (default on reset)
1
Internal oscillator 1 continues to function in HALT mode. This feature can be used to allow
the internal oscillator to continue clocking when HALT mode is active. This would enable a
quicker wake-up from HALT.
8
INTOSC1OFF
Internal Oscillator 1 Off bit. This bit turns oscillator 1 off:
0
Internal oscillator 1 On (default on reset)
1
Internal oscillator 1 Off. This bit could be used by the user to turn off the internal oscillator 1
if it is not used. This selection is not affected by the missing clock detect circuit.
7-5
TMR2CLKPRESCALE
CPU Timer 2 Clock Pre-Scale Value. These bits select the pre-scale value for the selected
clock source for CPU Timer 2. This selection is not affected by the missing clock detect
circuit.
000
/1 (default on reset)
001
/2
010
/4
011
/8
100
/16
101
Reserved
110
Reserved
111
Reserved
4-3
TMR2CLKSRCSEL
CPU Timer 2 Clock Source Select bit. This bit selects the source for CPU Timer 2.
00
SYSCLKOUT selected (default on reset, pre-scaler is bypassed)
01
External oscillator selected (at XOR output)
10
Internal oscillator 1 selected
11
Internal oscillator 2 selected. This selection is not affected by the missing clock detect
circuit.
2
WDCLKSRCSEL
Watchdog Clock Source Select bit. This bit selects the source for the watchdog clock. On
XRS low and after XRS goes high, internal oscillator 1 is selected by default. You need to
select external oscillator or internal oscillator 2 during their initialization process. If missing
clock detect circuit detects a missing clock, then this bit is forced to 0 and internal oscillator
1 is selected. The user changing this bit does not affect the PLLCR value.
0
Internal oscillator 1 selected (default on reset)
1
External oscillator or Internal oscillator 2 selected
1
OSCCLKSRC2SEL
Oscillator 2 Clock Source Select bit. This bit selects between internal oscillator 2 or external
oscillator. This selection is not affected by the missing clock detect circuit.
0
External oscillator selected (default on reset)
1
Internal oscillator 2 selected
System Control and Interrupts
74
TMS320x2806x Microcontrollers
SPRUH18I – JANUARY 2011 – REVISED JUNE 2022
Copyright © 2022 Texas Instruments Incorporated