6.4.6 Interrupt Control
Operation and features of the eCAP interrupt control include (see
):
• An interrupt can be generated on capture events (CEVT1-CEVT4, CTROVF) or APWM events (CTR = PRD,
CTR = CMP).
• A counter overflow event (FFFFFFFF->00000000) is also provided as an interrupt source (CTROVF).
• The capture events are edge and sequencer-qualified (ordered in time) by the polarity select and Mod4
gating, respectively.
• One of these events can be selected as the interrupt source (from the eCAPx module) going to the PIE.
• Seven interrupt events (CEVT1, CEVT2, CEVT3, CEVT4, CNTOVF, CTR=PRD, CTR=CMP) can be
generated.
• The interrupt enable register (ECEINT) is used to enable/disable individual interrupt event sources. The
interrupt flag register (ECFLG) indicates if any interrupt event has been latched and contains the global
interrupt flag bit (INT). An interrupt pulse is generated to the PIE only if any of the interrupt events are
enabled, the flag bit is 1, and the INT flag bit is 0. The interrupt service routine must clear the global interrupt
flag bit and the serviced event via the interrupt clear register (ECCLR) before any other interrupt pulses are
generated. You can force an interrupt event via the interrupt force register (ECFRC). This is useful for test
purposes.
Note
The CEVT1, CEVT2, CEVT3, CEVT4 flags are only active in capture mode (ECCTL2[CAP/APWM
== 0]). The CTR=PRD, CTR=CMP flags are only valid in APWM mode (ECCTL2[CAP/APWM == 1]).
CNTOVF flag is valid in both modes.
Enhanced Capture (eCAP)
438
TMS320x2806x Microcontrollers
SPRUH18I – JANUARY 2011 – REVISED JUNE 2022
Copyright © 2022 Texas Instruments Incorporated