13.14.2.12 SCI FIFO Control (SCIFFCT) Register (Offset = Ch) [reset = 0h]
SCIFFCT contains the status of auto-baud detect, clears the auto-baud flag, and calibrate for A-detect bit.
Figure 13-22. SCI FIFO Control (SCIFFCT) Register
15
14
13
12
11
10
9
8
ABD
ABDCLR
CDC
RESERVED
R-0h
W-0h
R/W-0h
R-0h
7
6
5
4
3
2
1
0
FFTXDLY
R/W-0h
Table 13-19. SCI FIFO Control (SCIFFCT) Register Field Descriptions
Bit
Field
Type
Reset
Description
15
ABD
R
0h
Auto-baud detect (ABD) bit
Reset type: SYSRSn
0h (R/W) = Auto-baud detection is not complete. "A","a" character
has not been received successfully.
1h (R/W) = Auto-baud hardware has detected "A" or "a" character on
the SCI receive register. Auto-detect is
complete.
14
ABDCLR
W
0h
ABD-clear bit
Reset type: SYSRSn
0h (R/W) = Write 0 has no effect on ABD flag bit. Bit reads back a
zero.
1h (R/W) = Write 1 to clear ABD flag in bit 15.
13
CDC
R/W
0h
CDC calibrate A-detect bit
Reset type: SYSRSn
0h (R/W) = Disables auto-baud alignment
1h (R/W) = Enables auto-baud alignment
12-8
RESERVED
R
0h
Reserved
7-0
FFTXDLY
R/W
0h
FIFO transfer delay. These bits define the delay between every
transfer from FIFO transmit buffer to transmit shift register. The delay
is defined in the number of SCI serial baud clock cycles. The 8 bit
register could define a minimum delay of 0 baud clock cycles and a
maximum of 256 baud clock cycles.
In FIFO mode, the buffer (TXBUF) between the shift register and
the FIFO should be filled only after the shift register has completed
shifting of the last bit. This is required to pass on the delay between
transfers to the data stream. In FIFO mode, TXBUF should not be
treated as one additional level of buffer. The delayed transmit feature
will help to create an auto-flow scheme without RTS/CTS controls as
in standard UARTS.
When SCI is configured for one stop-bit, delay introduced by
FFTXDLY between one frame and the next frame is equal to number
of baud clock cycles that FFTXDLY is set to.
When SCI is configured for two stop-bits, delay introduced by
FFTXDLY between one frame and the next frame is equal to number
of baud clock cycles that FFTXDLY is set to minus 1.
Reset type: SYSRSn
Serial Communications Interface (SCI)
SPRUH18I – JANUARY 2011 – REVISED JUNE 2022
TMS320x2806x Microcontrollers
831
Copyright © 2022 Texas Instruments Incorporated
Содержание TMS320 2806 Series