16.9.17 eCAN I/O Control Registers (CANTIOC, CANRIOC)
The CANTX and CANRX pins should be configured for CAN use. This is done using the CANTIOC and
CANRIOC registers.
Figure 16-30. TX I/O Control Register (CANTIOC)
31
16
Reserved
R-0
15
4
3
2
0
Reserved
TXFUNC
Reserved
R-0
RWP-0
LEGEND: RWP = Read in all modes, write in EALLOW-mode only; R = Read only; -
n
= value after reset
Table 16-26. TX I/O Control Register (CANTIOC) Field Descriptions
Bit
Field
Value
Description
31:4
Reserved
Reads are undefined and writes have no effect.
3
TXFUNC
This bit must be set for CAN module function.
1
The CANTX pin is used for the CAN transmit functions.
0
Reserved
2:0
Reserved
Reserved
Figure 16-31. RX I/O Control Register (CANRIOC)
31
16
Reserved
R-x
15
4
3
2
0
Reserved
RXFUNC
Reserved
R-0
RWP-0
LEGEND: RWP = Read in all modes, write in EALLOW-mode only; R = Read only; -
n
= value after reset; x = indeterminate
Table 16-27. RX I/O Control Register (CANRIOC) Field Descriptions
Bit
Field
Value
Description
31:4
Reserved
Reads are undefined and writes have no effect.
3
RXFUNC
This bit must be set for CAN module function.
1
The CANRX pin is used for the CAN receive functions.
0
Reserved
2:0
Reserved
Reserved
Controller Area Network (CAN)