Status Word Definitions 5-127
SR785 Dynamic Signal Analyzer
Display Status Word
Bit Name Set
when
0
NEWA
New data is available for DisplayA
1
AVGA
DisplayA linear average has completed
2
STLA
New settled data is available for DisplayA
3
LIMA
DisplayA has failed a limit test
4
SSA
Swept Sine sweep has finished
5
WFA
Display A 1-shot Waterfall has finished
6
WFD
Display A Waterfall has finished drawing
7 unused
8
NEWB
New data is available for DisplayB
9
AVGB
DisplayB linear average has completed
10
STLB
New settled data is available for DisplayB
11
LIMB
DisplayB has failed a limit test
12
SSB
Swept Sine sweep has finished
13
WFB
Display B 1-shot Waterfall has finished
14
WFB
Display B Waterfall has finished drawing
15 unused
The Display status bits stay set until read by DSPS?. They are also cleared by the
*CLS command. Use DSPE to set bits in the Display status enable register.
The AVG, STL, LIM and SS bits are only updated when new data is available
for the display (no faster than 8 Hz). Always test for NEWA or NEWB in the
status word along with AVG, STL, LIM or SS.
The status updates for the two displays may not be exactly synchronous. Always
test the DisplayA status bits separately from the DisplayB status bits. For
example, to wait for both displays to finish averaging, do NOT test the Display
status word for both AVGA and AVGB simultaneously. The AVGA and AVGB
bits may not be set at the same time. Test for AVGA and AVGB separately and
wait until both have occurred.