Input
Commands
5-65
SR785 Dynamic Signal Analyzer
Input Playback Commands
ISTR (?) {i}
The ISTR command sets (queries) the Capture Playback Start point. The
parameter i is a point in the Capture buffer.
This command is valid only when the Input Source is Playback.
ILEN (?) {i}
The ILEN command sets (queries) the Capture Playback Length. The parameter i
is the length in kPts in the Capture buffer. i must be an even number from 2 to
the length of the waveform.
This command is valid only when the Input Source is Playback.
IMOD (?) {i}
The IMOD command sets (queries) the Capture Playback Mode. The parameter i
selects 1-Shot (0) or Circular (1).
This command is valid only when the Input Source is Playback.
ISPD (?) {i}
The ISPD command sets (queries) the Capture Playback Speed. The parameter i
selects Normal (0) or Every Frame (1).
This command is valid only when the Input Source is Playback.