5-58 Source
Commands
SR785 Dynamic Signal Analyzer
Swept Sine Source Commands
SSAL (?) {i}
The SSAL command sets (queries) the Auto Level Reference. The parameter i
selects Off (0), Channel 1 (1) or Channel 2 (2).
This command is valid only when the Measurement Group is Swept Sine.
SSAM (?) {x} <mV, [V[, dBVpk>
The SSAM command sets (queries) the Swept Sine Amplitude. The parameter x
is the amplitude in the specified units. The query returns two numbers of the
form y,i where y is a real number and i is an index indicating the units.
This command is valid only when the Measurement Group is Swept Sine and
Auto Level Reference is Off.
SSRF (?) {x} <mV, [V[, dBVpk>
The SSRF command sets (queries) the Swept Sine Ideal Reference. The
parameter x is the ideal reference in the specified units. The query returns two
numbers of the form y,i where y is a real number and i is an index indicating the
units.
This command is valid only when the Measurement Group is Swept Sine and
Auto Level Reference is Ch1 or Ch2.
SRMP (?) {i}
The SRMP command sets (queries) the Swept Sine Source Ramping. The
parameter i selects Off (0) or On (1).
This command is valid only when the Measurement Group is Swept Sine.
SRAT (?) {x}
The SRAT command sets (queries) the Swept Sine Source Ramp Rate. The
parameter x is the ramp rate in V/s.
This command is valid only when the Measurement Group is Swept Sine.
SSUL (?) {x}
The SSUL command sets (queries) the Swept Sine Reference Upper Limit. The
parameter x is a ratio in dB from 0.1 to 30.0 dB.
This command is valid only when the Measurement Group is Swept Sine and
Auto Level Reference is Ch1 or Ch2.