PS220 Configuration & Operation Guide
PS220 218
Functions &
Features
Procedure for properly configuring and performing a SMARTFLOW TUNE with liquids with SG other than water
(1.0 S.G.) at a customers’ facility.
This procedure should be followed for both Basic and Advanced Smartflow.
This example will use a case study from a Goulds Model 3420, pumping a light Hydrocarbon with an actual
Specific Gravity (S.G.) of liquid in the pump of .85. (Lighter than water)
1. Use the BASIC Smartflow Wizard as noted is this manual by calculating inputting all the necessary information
from the pump curve below for water 1.0 SG.
CAUTION
Failure to follow the guidelines in this section can result in serious physical injury,
death and/or equipment damage.
Using information from this test curve at 710 RPM:
Units are: GPM (viewable only)
85.27
DS Centrifugal (Model 3420)
77.01
BHP Calc Method
77.02
BEP Flow 5200 GPM
77.03
Pump Speed 710 RPM
77.04
BEP Power 69.65
77.05
SO Power (estimated at 9.5)
77.06
Q Act Filter 5 Seconds
77.23
SG Rated: 1.0 ALWAYS PRIOR TO TUNING!
78.03
Содержание PumpSmart PS220
Страница 1: ...Configuration Operation Manual PumpSmart Control Solutions PS220 v6 05...
Страница 5: ...PS220 Configuration Operation Guide PS220 4 Getting Started THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 9: ...PS220 Configuration Operation Guide PS220 8 Basic Startup THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 22: ...PS220 Configuration Operation Guide 21 PS220 SmartFlow...
Страница 40: ...PS220 Configuration Operation Guide 39 PS220 Process Control THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 217: ...PS220 Configuration Operation Guide PS220 216 Functions Features This is an example of a typical Pump Performance Curve...
Страница 261: ...PS220 Configuration Operation Guide PS220 260 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 283: ...PS220 Configuration Operation Guide PS220 282 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 289: ...PS220 Configuration Operation Guide PS220 288 Ecodesign Regulation...
Страница 292: ...PS220 Configuration Operation Guide 291 PS220 Fuses heat dissipation chart...