2-10
Installation conditions TLC 1000 and TLC 1005 - Version 5
B337EN02.DOC
1.5 Exhaust air conduction for compact
dust extractor
If needed, the exhaust air conduit for the compact dust extractor
can be installed to allow the release of clear gas into the open air.
The exhaust air conduit must be installed by the customer starting
from the clear gas duct of the compact dust extractor.
The pipeline must be configured as follows:
•
Maximum of two 90° bends (radius = diameter x 1.5).
•
Max. length: 10 m.
•
Tube diameter: 250 mm.
•
Flange design according to DIN 21254-R2.
Note
If any other configurations are used, a ventilation technician or the
manufacturer of the compact dust extractor must be consulted.
In all cases, the maximum resistance of 10 daPa (= 100 Pa) must
not be exceeded!
300
Ø
25
3
Ø 2
92
56
5
M10 (8x)
Connection of DELTA 1200-12/9 SC clear gas duct
Pipeline
Clear gas duct connection
Fig. 35910
Summary of Contents for LASERCELL 1005
Page 1: ...Operator s manual TRUMPF LASERCELL 1005...
Page 2: ......
Page 3: ...Operator s manual TRUMPF LASERCELL 1005 Edition 07 2004...
Page 6: ...0 6 Before You proceed B337EN00 DOC...
Page 22: ...0 22 Table of Contents B337EN00 DOC...
Page 23: ...1...
Page 61: ...1 38 Laser processing B337EN01 DOC...
Page 62: ...2...
Page 107: ...3...
Page 160: ...4...
Page 408: ...4 248 Operation B337EN4_8 Fig 36634 Fig 36630 4 Select Backup to ZIP press 4 5 Press Enter...
Page 412: ...4 252 Operation B337EN4_8...
Page 413: ...5...
Page 515: ...5 102 Further service programs B337EN05 DOC...
Page 516: ...6...
Page 589: ...7...
Page 628: ...8...
Page 636: ...8 8 Cross hairs to cut out B337EN08 DOC...
Page 637: ...9...
Page 643: ...9 6 Diagram Location of measuring points B337EN09 DOC...
Page 644: ...10...