4-104
Operation
B337EN4_4
Switch elements of the distance control
system
Fig. 39017en
Switch elements for
distance control system
•
Teach probe: press the switch element to work with the teach
probe. The following apply when operating with the teach
probe:
-
The DIAS III distance control system is not active.
-
It is not possible to ignite the laser.
-
It is not possible to open the beam trap.
•
Record DIAS curve: press the switch element to record the
DIAS characteristic curve. The DIAS characteristic curve can
only be recorded if the distance control system is switched on.
•
Distance control system: press the switch to switch the
distance control system on or off.
•
DIAS record: in order to log process data relating to the
distance control system, for servicing purposes: press the
switch element to save the process data from the last 10
seconds onto diskette. To do this, a diskette has to be inserted
in the DIAS computer in the switch cabinet of the machine.
FEED HOLD is triggered during the recording and the drives
are switched off. To cancel FEED HOLD: press MACHINE ON
and then RESET.
Summary of Contents for LASERCELL 1005
Page 1: ...Operator s manual TRUMPF LASERCELL 1005...
Page 2: ......
Page 3: ...Operator s manual TRUMPF LASERCELL 1005 Edition 07 2004...
Page 6: ...0 6 Before You proceed B337EN00 DOC...
Page 22: ...0 22 Table of Contents B337EN00 DOC...
Page 23: ...1...
Page 61: ...1 38 Laser processing B337EN01 DOC...
Page 62: ...2...
Page 107: ...3...
Page 160: ...4...
Page 408: ...4 248 Operation B337EN4_8 Fig 36634 Fig 36630 4 Select Backup to ZIP press 4 5 Press Enter...
Page 412: ...4 252 Operation B337EN4_8...
Page 413: ...5...
Page 515: ...5 102 Further service programs B337EN05 DOC...
Page 516: ...6...
Page 589: ...7...
Page 628: ...8...
Page 636: ...8 8 Cross hairs to cut out B337EN08 DOC...
Page 637: ...9...
Page 643: ...9 6 Diagram Location of measuring points B337EN09 DOC...
Page 644: ...10...