B337EN02.DOC
Installation conditions TLC 1000 and TLC 1005 - Version 5
2-21
O
2
Standard
pressure
O
2
High pressure
8
N
2
High pressure
1st pressure stage
(tank)
Safety pressure
regulating system
9
Optional
Recommended
Recommended
2nd pressure stage
(tapping point)
Tapping point
pressure regulator
Recommended
Recommended
Not
recommended
Back pressure
[bar] 0 - 16
4 - 25
-
Other requirements
Suitable for
oxygen, free of
oil and grease
Suitable for
oxygen, free of
oil and grease
Oil and grease-
free
Cutting gas supply – pressure control specification
O
2
Standard
pressure
O
2
High pressure
8
N
2
High pressure
Min. input pressure
line pressure in
[bar] 8
15
27
Max. input pressure
static
10
[bar] 21
21
34
Max. cutting gas
pressure [bar] 6
12
20
Volume rate of flow
11
[Nm³/h] 10
20
55
Nozzle diameter
[mm] 1.7
1.7
2.3
Cutting gas supply – machine connection
9
The safety pressure regulation system is installed close to the tank.
It provides for uniform pressure in the network. The built-in pressure relief
valve ensures that the gases are released outside in case of accident.
This helps avoid any endangerment in the area around the laser machine
due to concentration of oxygen (O
2
) or depletion of oxygen (N
2
).
10
The machine is equipped with blow-off valves that respond when there is
high input pressure, thereby creating a whistling sound.
11
The volume rate of flow is reached when selecting maximum cutting gas
pressure and specifying nozzle diameter.
Pressure regulator
specifications
Table 2-13
Requirements at the
connection point
on the machine
Table 2-14
Summary of Contents for LASERCELL 1005
Page 1: ...Operator s manual TRUMPF LASERCELL 1005...
Page 2: ......
Page 3: ...Operator s manual TRUMPF LASERCELL 1005 Edition 07 2004...
Page 6: ...0 6 Before You proceed B337EN00 DOC...
Page 22: ...0 22 Table of Contents B337EN00 DOC...
Page 23: ...1...
Page 61: ...1 38 Laser processing B337EN01 DOC...
Page 62: ...2...
Page 107: ...3...
Page 160: ...4...
Page 408: ...4 248 Operation B337EN4_8 Fig 36634 Fig 36630 4 Select Backup to ZIP press 4 5 Press Enter...
Page 412: ...4 252 Operation B337EN4_8...
Page 413: ...5...
Page 515: ...5 102 Further service programs B337EN05 DOC...
Page 516: ...6...
Page 589: ...7...
Page 628: ...8...
Page 636: ...8 8 Cross hairs to cut out B337EN08 DOC...
Page 637: ...9...
Page 643: ...9 6 Diagram Location of measuring points B337EN09 DOC...
Page 644: ...10...