Installation conditions TLC 1000 and TLC 1005 - Version 5
2-9
1.4 Ambient
conditions
The ambient temperature for the operation of the machine must be
b10 °C and +43 °C. The temperature at the installation
site must not be allowed to fall below +4 °C when the system is
switched off.
Note
One-sided exposure to direct sunlight and unidirectional drafts
(heat distortion) must be avoided (e.g. with Venetian blinds if the
control unit is set up at a window).
To prevent deterioration of beam quality, ensure that the
installation site of the laser is free of particles or substances which
absorb radiation with a wave length of 10.6 µm. These are e.g.
solvent gases, which are released when enameling, that come
from the degreasing units.
If the ambient temperature is b35 °C - +43 °C the system
must be equipped with the tropical version of the laser.
The control system is cooled by inner air circulation in the closed
control cabinet. This ensures that components are extensively
protected against dirt and dust.
The heat dissipation from the control system housings is normally
performed by external heat exchangers with fans which suck in air
directly and blow it along the cooling elements. Make sure that
there is no excessive air contamination in the intake region of the
fan behind the control system, as dust on the cooling elements
greatly reduces heat transfer.
Damp rooms are not suitable for the operation of the control
systems, principally because contact corrosion may develop on
contactor and relay contacts, leading to control errors.
Ambient temperature
Ambient air
Tropical version
of the laser
Cooling of the
control system
Summary of Contents for LASERCELL 1005
Page 1: ...Operator s manual TRUMPF LASERCELL 1005...
Page 2: ......
Page 3: ...Operator s manual TRUMPF LASERCELL 1005 Edition 07 2004...
Page 6: ...0 6 Before You proceed B337EN00 DOC...
Page 22: ...0 22 Table of Contents B337EN00 DOC...
Page 23: ...1...
Page 61: ...1 38 Laser processing B337EN01 DOC...
Page 62: ...2...
Page 107: ...3...
Page 160: ...4...
Page 408: ...4 248 Operation B337EN4_8 Fig 36634 Fig 36630 4 Select Backup to ZIP press 4 5 Press Enter...
Page 412: ...4 252 Operation B337EN4_8...
Page 413: ...5...
Page 515: ...5 102 Further service programs B337EN05 DOC...
Page 516: ...6...
Page 589: ...7...
Page 628: ...8...
Page 636: ...8 8 Cross hairs to cut out B337EN08 DOC...
Page 637: ...9...
Page 643: ...9 6 Diagram Location of measuring points B337EN09 DOC...
Page 644: ...10...