7-38
Maintenance of laser
B337EN07.doc
7.4 Checking generator values
•
Switch on laser unit.
Caution
The operating values are measured while the unit is in service
mode. Operational errors may result in beam emission at the
machining head. To determine the operating values, perform the
following steps only:
•
Switch to service mode using the key switch.
•
Select the Focus button.
•
Select 2 Diagnostics – 6 Laser – 1 RF generator in the menu
bar.
•
Confirm with the Toggle key.
•
Select the Focus button.
•
Select the CW operation mode.
•
Set RF amplitude to 100 %.
•
Press the softkey Confirm selection.
•
Select the Update display softkey.
•
Activate beam.
LASER