B337EN4_4
Operation
4-105
Note:
When it recognizes a collision, the distance control system can not
distinguish between a true collision between optics and workpiece
and a "spray collision" during the process. For this reason, the user
has the opportunity of adjusting the reaction time of the distance
control system to match the respective task.
•
Collision recognition: press the switch element when the
reaction time of the distance control system is to be modified.
The reaction time of the distance control system after a
recognized collision will be influenced with this switch element
until the triggering of FEED HOLD. The selected reaction time
is self-holding. There are 3 variants:
-
Slow 2-D: slow reaction time for the processing of flat
sheets.
-
Medium 3-D: medium reaction time for 3-D processing.
-
High: rapid reaction time for special applications.
Summary of Contents for LASERCELL 1005
Page 1: ...Operator s manual TRUMPF LASERCELL 1005...
Page 2: ......
Page 3: ...Operator s manual TRUMPF LASERCELL 1005 Edition 07 2004...
Page 6: ...0 6 Before You proceed B337EN00 DOC...
Page 22: ...0 22 Table of Contents B337EN00 DOC...
Page 23: ...1...
Page 61: ...1 38 Laser processing B337EN01 DOC...
Page 62: ...2...
Page 107: ...3...
Page 160: ...4...
Page 408: ...4 248 Operation B337EN4_8 Fig 36634 Fig 36630 4 Select Backup to ZIP press 4 5 Press Enter...
Page 412: ...4 252 Operation B337EN4_8...
Page 413: ...5...
Page 515: ...5 102 Further service programs B337EN05 DOC...
Page 516: ...6...
Page 589: ...7...
Page 628: ...8...
Page 636: ...8 8 Cross hairs to cut out B337EN08 DOC...
Page 637: ...9...
Page 643: ...9 6 Diagram Location of measuring points B337EN09 DOC...
Page 644: ...10...