B337EN06.doc
Machine maintenance
6-67
Maintenance point no.
Interval
operating
hours
Maintenance note
Procedure
73
MMC buffer battery
in control panel
Part no.: 0143467
Fig. 31775
Every
3 years
starting
from
Siemens’
delivery
date
Battery replacement
Caution, loss of data!
The battery may only be replaced when the machine
control system is switched on. If the battery is changed
with the MAIN SWITCH off, the data stored on the hard
drive of the MMC are lost.
1. Switch on MAIN SWITCH.
2. Remove the cover on the rear side of the control
panel.
3.
Pull out the battery plug (2).
4.
Remove battery (1).
5.
Put in a new battery, ensuring the polarity is correct.
6.
Insert the battery plug (2).
7.
Close the cover.
MMC battery – rear side of control panel
Fig. 31775
1
2
1
Battery
2
Battery plug
Summary of Contents for LASERCELL 1005
Page 1: ...Operator s manual TRUMPF LASERCELL 1005...
Page 2: ......
Page 3: ...Operator s manual TRUMPF LASERCELL 1005 Edition 07 2004...
Page 6: ...0 6 Before You proceed B337EN00 DOC...
Page 22: ...0 22 Table of Contents B337EN00 DOC...
Page 23: ...1...
Page 61: ...1 38 Laser processing B337EN01 DOC...
Page 62: ...2...
Page 107: ...3...
Page 160: ...4...
Page 408: ...4 248 Operation B337EN4_8 Fig 36634 Fig 36630 4 Select Backup to ZIP press 4 5 Press Enter...
Page 412: ...4 252 Operation B337EN4_8...
Page 413: ...5...
Page 515: ...5 102 Further service programs B337EN05 DOC...
Page 516: ...6...
Page 589: ...7...
Page 628: ...8...
Page 636: ...8 8 Cross hairs to cut out B337EN08 DOC...
Page 637: ...9...
Page 643: ...9 6 Diagram Location of measuring points B337EN09 DOC...
Page 644: ...10...