13. Trip information and measures
I
II
III
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
CHn
Setting for China
Setting for China is selected in the setup
menu.
-
CLr
Reset command
acceptable
The following was operated after trip is
occurring.
1) Pressed [STOP] key once.
2) Set the reset terminal ON.
(During trip resetting operation)
Reset is performed with the following
operation.
1) Press [STOP] key again.
2) Set the reset terminal OFF.
db
During DC braking
DC braking in progress.
-
dbOn
During motor shaft
fixing
Motor shaft fixing in progress.
A message indicates the motor fixing control
in progress. When standby is turned OFF, the
control stops.
E1
Panel display one
digit overflow
The display digit on the operation panel
overflowed by one digit.
-
E2
Panel display two
digits overflow
The display digit on the operation panel
overflowed by two digits.
-
E3
Panel display three
digits overflow
The display digit on the operation panel
overflowed by three digits.
-
EASy
Easy mode
Switched to [Easy mode].
-
End
Last of data
The last data item in <History function>.
-
EOFF
Emergency off
command
acceptable
When a run command is other than the
operation panel, [STOP/RESET] key was
pressed once.
To apply emergency off, press [STOP] key
again.
If emergency off does not occur, press other
keys.
Err1
Frequency point
setting error
The setting on point 1 and point 2 of the
frequency command is close.
Set apart point 1 and point 2 of the frequency
command.
EU
Setting for Europe
Setting for Europe is selected in the setup
menu.
-
FAIL
Password failure
Entered number in <F739: Password
verification> does not match <F738:
Password setting>.
-
FIrE
During Fire speed
run/Forced run
Fire speed run/Forced run is in progress.
("FIrE" and the output frequency are
alternately displayed)
A message indicates fire speed run/forced
run in progress. It stops when turning the
power OFF.
FJOG
Fwd JOG
Forward jog run in progress.
-
HEAd
Head of data
The first data item in <History function>.
-
HI
Upper limit of
setting value
The upper limit of the setting value.
-
Init
During Initializing
• Set <tyP: Default setting> = "3" or "13" and
initialization is in progress.
• Region setting in progress with the setup
menu.
No problem if the display shows "0.0" after
several seconds.
JP
Setting for Japan
Setting for Japan is selected in the setup
menu.
-
LO
Lower limit of
setting value
The lower limit of the setting value.
-
LStP
During run sleep
Run sleep in progress.
-
n---
No detailed
information of past
trip
While "nErr" and a value are alternately
displayed, [OK] key is pressed and detailed
information are read.
Normal display.
Message
display
English
Description
Remarks
Summary of Contents for TOSVERT VF-AS3
Page 2: ...1 9 ...
Page 14: ......
Page 17: ...E6582062 iii I 3 9 15 Warranty 15 1 16 Disposal 16 1 ...
Page 18: ......
Page 34: ......
Page 438: ......
Page 458: ......
Page 470: ......
Page 482: ......
Page 502: ......
Page 572: ......
Page 590: ......
Page 608: ......
Page 616: ......
Page 618: ......
Page 620: ......
Page 621: ...1 3 9 10 ...