5. [Fundamental operation] How to use parameters
5-76
4
5
9
Important
• This parameter is a function to display the output frequency of the inverter multiplied by the
factor. It does not display the actual motor speed or line speed precisely.
800
80 (Hz)
Output frequency (Hz)
0
0
800
Panel display
Panel display
80 (Hz)
Output frequency (Hz)
0
0
1000
200
80 (Hz)
Output frequency (Hz)
0
0
Panel display
Positive inclination
Negative inclination
Positive inclination with bias
<F702>
<F702>
<F702>
<F705>="1 ", <F706>="0.00"
<F705>="0", <F706>="80.00"
<F705>="1", <F706>="20.00"