E6582062
4-41
4. [Basic operation] Operation methods of motor
3
4
9
13 Press the [OK] key.
The screen returns to the basic parameter screen.
14 Similarly, select <Sr2: Preset speed 2> and <Sr3:
Preset speed 3> and change the setting values.
In the example on the right, <Sr2: Preset speed 2>
is set to 10.0 Hz and <Sr3: Preset speed 3> to 15.0
Hz.
15 Press the [OK] key to return to the basic parameter screen.
16 Turn on the external switch.
Leave the two relays off.
17 When you turn on relay 1, the frequency command value of <Sr1> is enabled, and the motor
starts running.
In the main area of the [Standard mode] screen, the output frequency is displayed.
0.0Hz
STOP
15:59
Basic parameters
dEC
: Deceleration time 1
Sr0
: Preset speed 0
Sr3
: Preset speed 3
10.0s
0.0Hz
0.0Hz
Sr1
: Preset speed 1
20.0Hz
Sr2
: Preset speed 2
10.0Hz
F
R
0.0Hz
STOP
15:59
Basic parameters
dEC
: Deceleration time 1
Sr0
: Preset speed 0
10.0s
0.0Hz
Sr1
: Preset speed 1
20.0Hz
Sr2
: Preset speed 2
10.0Hz
Sr3
: Preset speed 3
15.0Hz
F
R