E6582062
6. [Advanced] How to use parameters
6-12
4
4
6
9
6. 3. 1
Always enabling the input terminal functions
(always ON)
<F110: Always active function 1>
<F127: Always active function 2>
<F128: Always active function 3>
■
Function
These parameters select an input terminal function to be always enabled (always ON). You can set
three points.
■
Parameter setting
6. 3
Selecting terminal functions
Title
Parameter name
Adjustment range
Default setting
F110
Always active function 1
0-177
*1
*1 For details on the input terminal functions, refer to [7. 2. 1].
6
F127
Always active function 2
0
F128
Always active function 3
0
6: Standby
7:
6(Invers)
8: Reset 1
9:
8(Invers)
10: Preset speed switching 1
0.0Hz
STOP
12:47
F110 : Always active function 1