E6582062
4-9
4. [Basic operation] Operation methods of motor
3
4
9
List of parameters changeable by guidance function
Embedded Ethernet setting
<AUF>=1
C081-C096
Device name 1-16
C610
Emb Eth. IP setting mode
C611-C614
Emb Eth. IP address setting value
C615-C618
Emb Eth. Subnet mask setting value
C619-C622
Emb Eth. Default gateway setting
value
C629-C632
Emb Eth. IP address monitor
C633-C636
Emb Eth. Subnet mask monitor
C637-C640
Emb Eth. Default gateway monitor
Preset speed operation
<AUF>=2
CMOd
Run command select
FMOd
Frequency command select 1
ACC
Acceleration time 1
dEC
Deceleration time 1
FH
Maximum frequency
UL
Upper limit frequency
Sr1-Sr7
Preset speed 1-7
F111-F116
Terminal xx function
F287-F294
Preset speed 8-15
Analog frequency command
<AUF>=3
CMOd
Run command select
FMOd
Frequency command select 1
ACC
Acceleration time 1
dEC
Deceleration time 1
FH
Maximum frequency
UL
Upper limit frequency
LL
Lower limit frequency
F201
RR point 1 input value
F202
RR point 1 frequency
F203
RR point 2 input value
F204
RR point 2 frequency
F216
II point 1 input value
F217
II point 1 frequency
F218
II point 2 input value
F219
II point 2 frequency
Motor 1,2 switching
<AUF>=4
vL
Base frequency 1
vLv
Base frequency voltage 1
vb
Manual torque boost 1
tHrA
Motor overload protection current 1
ACC
Acceleration time 1
dEC
Deceleration time 1
F111-F116
Terminal xx function
F170
Base frequency 2
F171
Base frequency voltage 2
F172
Manual torque boost 2
F182
Motor overload protection current 2
F185
Stall prevention level 2
F415
Motor rated current
F500
Acceleration time 2
F501
Deceleration time 2
F601
Stall prevention level 1
Motor parameter
<AUF>=5
Pt
V/f pattern
vL
Base frequency
vLv
Base frequency voltage 1
F405
Motor rated capacity
F415
Motor rated current
F417
Motor rated speed
F400
Offline auto-tuning
PM motor parameter
<AUF>=6
Pt
V/f pattern
vL
Base frequency 1
vLv
Base frequency voltage 1
F402
Automatic torque boost
F405
Motor rated capacity
F415
Motor rated current
F417
Motor rated speed
F458
Current control response
F460
Speed control response 1
F461
Speed control stabilization coefficient 1
F462
Speed reference filter coefficient 1
F910
PM step-out detection current level
F911
PM step-out detection time
F912
PM q-axis inductance
F913
PM d-axis inductance
F914
Parameter for manufacturer
F915
PM control method
F916
PM starting current
F917
IPM maximum torque control
F918
IPM current phase adjustment
F919
Parameter for manufacturer
F400
Offline auto-tuning
Summary of Contents for TOSVERT VF-AS3
Page 2: ...1 9 ...
Page 14: ......
Page 17: ...E6582062 iii I 3 9 15 Warranty 15 1 16 Disposal 16 1 ...
Page 18: ......
Page 34: ......
Page 438: ......
Page 458: ......
Page 470: ......
Page 482: ......
Page 502: ......
Page 572: ......
Page 590: ......
Page 608: ......
Page 616: ......
Page 618: ......
Page 620: ......
Page 621: ...1 3 9 10 ...