12-1
12. Specifications
I
II
III
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
In this chapter, the inverter's model and type, standard specification, outside dimensions, and
approx. mass are described.
■
Standard specification depending on model
< 240 V class: HD rating >
12
Specifications
12. 1 Model and main standard specification
Item
Specification
Voltage class
240 V class
Frame size
A1
A2
A3
A4
A5
A6
Applicable motor (kW)
0.4
0.75
1.5
2.2
4.0
5.5
7.5
11
15
18.5
22
30
37
45
55
Applicable motor (HP)
0.5
1
2
3
5
7.5
10
15
20
25
30
40
50
60
75
Rating
Type
VFAS3-
Form
2004P 2007P 2015P 2022P 2037P 2055P 2075P 2110P 2150P 2185P 2220P 2300P 2370P 2450P 2550P
Output capacity (kVA)
*1
*1 Capacity is calculated at 220 V for the 240 V class.
1.3
1.8
3.0
4.3
7.1
9.7
12.5
17.8
24.2
29.9
35.3
46.9
56.8
67.1
80.4
Output current (A)
*2
*2 Indicates rated output current when setting <F300: Carrier frequency> into 4 kHz for frame size A1 to A5, 2.5 kHz for frame size A6.
3.3
4.6
8.0
11.2
18.7
25.4
32.7
46.8
63.4
78.4
92.6
123
149
176
211
Output voltage
3-phase 200 V to 240 V (The maximum output voltage is equal to the input supply voltage)
Overload current rating
150%-1 minute, 180%-2 s
Elec
trical
brak
ing
Dynamic braking circuit
Built-in
Optional
Dynamic braking resistor
External braking resistor (Optional)
Power supply
Voltage-frequency
3-phase 200 V to 240 V - 50/60 Hz
Allowable fluctuation
Voltage 170 V to 264 V
*3
, Frequency ± 5%
*3 Lower limit of voltage for 240 V class is 180 V when the inverter is used continuously (load of 100%).
Required power supply
capacity (kVA)
*4
*4 Required power supply capacity varies with the value of the power supply side inverter impedance (including those of the input reactor and wires).
0.7
1.4
2.4
3.7
5.9
7.7
10.5
15.7
20.6
24.9
30.7
40.5
49.6
61.0
73.3
Degree of protection (IEC60529)
IP20
IP00
Cooling method
Forced air-cooled
Cooling fan noise (dBA)
(Reference value)
*5
*5 These acoustic noise values are not guaranteed because they are just reference values.
58
54
60
64
63
70
Color
RAL7016 / RAL7035
EMC filter
No EMC filter
DC reactor
Built-in
UL type1 kit
Built-in
Optional
Summary of Contents for TOSVERT VF-AS3
Page 2: ...1 9 ...
Page 14: ......
Page 17: ...E6582062 iii I 3 9 15 Warranty 15 1 16 Disposal 16 1 ...
Page 18: ......
Page 34: ......
Page 438: ......
Page 458: ......
Page 470: ......
Page 482: ......
Page 502: ......
Page 572: ......
Page 590: ......
Page 608: ......
Page 616: ......
Page 618: ......
Page 620: ......
Page 621: ...1 3 9 10 ...