11. Table of parameters
11-64
1
9
11
32
33
E
Emergency off trip
ON: During emergency off trip ("E" is displayed)
34
35
RETRY
During retry
ON: During retry
36
37
PTNS
Pattern operation end
ON: All pattern operation end
38
39
PIDL
PID deviation limit
ON: Within the setting value of <F364: PID1 deviation upper-
limit>, <F365: PID1 deviation lower-limit>
40
41
RUN
Run/Stop
ON: During run or DC braking, OFF: During stop
42
43
HFL
Serious failure
ON: At trip
*1
, OFF: Other than those trip above
44
45
LFL
Slight failure
ON: At trip ("OC1", "OC2", "OC3", "OP1", "OP2", "OP3",
"OH", "OL1", "OL2", "OL3", "OLr")
OFF: Other than those trip above
46
47
CPSW1
Commercial power/
Inverter Switching 1
ON: For inverter run
48
49
CPSW2
Commercial power/
Inverter Switching 2
ON: For commercial power run
50
51
FAN
During cooling fan run
ON: During cooling fan run
52
53
JOG
During jog run
ON: During jog run
54
55
JBM
During terminal run
ON: During terminal run, OFF: Other than terminal run
56
57
COT
Cumulative run time
alarm
ON: Cumulative operation time is <F621: Cumulative run
time alarm > or more
58
59
COMOP
Communication option
communication time-out
ON: Time-out of communication option occurs (held until
reset)
60
61
FR
Fwd/Rev run
ON: During reverse run, OFF: During forward run
* Command direction or OFF during stop
62
63
RDY1
Ready for run 1
ON: Run when frequency command is ON
64
65
RDY2
Ready for run 2
ON: Run when ST, RUN, or frequency command is ON
68
69
BR
During brake
ON: Brake, OFF: Break release
70
71
PAL
During alarm or pre-alarm ON: Alarm or pre-alarm occuring
72
73
FSL
During Fwd speed limit
ON: <F426: Fwd speed limit level> or more (Torque control)
74
75
RSL
During Rev speed limit
ON: <F428: Rev speed limit level> or more (Torque control)
76
77
HLTH
Inverter healthy output
Output while switching ON and OFF over at every 1 sec. (to
check inverter soundness)
78
79
COME
RS485 communication
time-out
ON:RS485 communication time-out
92
93
DATA1
Designated data bit 0
ON: bit0 of FA50 is ON, OFF: bit0 of FA50 is OFF
94
95
DATA2
Designated data bit 1
ON: bit1 of FA50 is ON, OFF: bit1 of FA50 is OFF
106
107
LLD1
Light load detection 1
ON: Under heavy load torque(<F335> to <F338>)
108
109
HLD
Heavy load detection
ON: Heavy load torque(<F335> to <F338>)or more
110
111
PTL
During positive torque
limit
ON: During positive torque limit
112
113
MTL
During negative torque
limit
ON: During negative torque limit
114
115
RCRY
For external relay of rush
current suppression
ON: For external relay of rush current suppression
116
117
FL4
Failure signal 4
ON: During trip (including retry waite time)
Function Number
Symbol
Function
Action
Reference
Positive
logic
Negative
logic
Summary of Contents for TOSVERT VF-AS3
Page 2: ...1 9 ...
Page 14: ......
Page 17: ...E6582062 iii I 3 9 15 Warranty 15 1 16 Disposal 16 1 ...
Page 18: ......
Page 34: ......
Page 438: ......
Page 458: ......
Page 470: ......
Page 482: ......
Page 502: ......
Page 572: ......
Page 590: ......
Page 608: ......
Page 616: ......
Page 618: ......
Page 620: ......
Page 621: ...1 3 9 10 ...