6. [Advanced] How to use parameters
6-114
4
4
6
9
<F520: Pattern operation>
<F521: Pattern operation continue select>
<F522: Pattern 1 repeat number>
<F523: Pattern 1 select 1> to <F530: Pattern 1 select 8>
<F531: Pattern 2 repeat number>
<F532: Pattern 2 select 1> to <F539: Pattern 2 select 8>
<F540: Operation time (1-speed)> to <F554: Operation time
(15-speed)>
■
Function
You can perform terminal run according to up to 30 types (15 types x 2 patterns) of operation
frequencies, operation time, and acceleration/deceleration time that were set in advance.
Pattern operation switching, and Run/Stop are all input from the terminals.
■
Parameter setting
6. 28 Pattern operation
Title
Parameter name
Adjustment range
Unit
Default setting
F520
Pattern operation
0: Disabled
1: Enabled (seconds)
2: Enabled (minutes)
0
F521
Pattern operation
continue select
0: Reset after stop
1: Continue after stop
0
F522
Pattern 1 repeat number
1-254
255: Continuous
Times
1
F523-F530
Pattern 1 select 1-8
0: Skip
1: Sr1
2: Sr2
3: Sr3
4: Sr4
5: Sr5
6: Sr6
7: Sr7
8: F287
9: F288
10: F289
11: F290
12: F291
13: F292
14: F293
15: F294
0
F531
Pattern 2 repeat number
1-254
255: Continuous
Times
1
F532-F539
Pattern 2 select 1-8
Same as <F523>
0
F540-F554
Operation time
(1 to 15-speed)
0.1-5999
6000: Continuous
The
unit is
set at
<F
520>.
5.0
0.0Hz
STOP
13:52
F520 : Pattern operation
0: Disabled
1: Enabled (seconds)
2: Enabled (minutes)
Summary of Contents for TOSVERT VF-AS3
Page 2: ...1 9 ...
Page 14: ......
Page 17: ...E6582062 iii I 3 9 15 Warranty 15 1 16 Disposal 16 1 ...
Page 18: ......
Page 34: ......
Page 438: ......
Page 458: ......
Page 470: ......
Page 482: ......
Page 502: ......
Page 572: ......
Page 590: ......
Page 608: ......
Page 616: ......
Page 618: ......
Page 620: ......
Page 621: ...1 3 9 10 ...