E6582062
4. [Basic operation] Operation methods of motor
4-32
4
9
1
Turn off the power of the inverter.
2
Remove the covers of the control terminal block and parts required for connection.
Covers
to be removed vary depending on the type of the inverter.
For details of how to remove the covers, refer to [2. 2].
Reference
• How to switch the display mode of the operation panel -> Refer to [3. 1. 2]
• Procedure to change parameter setting -> Refer to [4. 2. 3]
• Details of <CMOd: Run command select>, and <FMOd: Frequency command select 1> ->
Refer to [5. 2. 1]
• Difference of connection between sink logic and source logic -> Refer to [2. 3. 5]
• Details of operation by external signals -> Refer to [Chapter 7]
R/L1
U/T1
V/T2
M
Motor
Common
Fwd run
Operation panel
W/T3
F
CC
PP
Voltage signal: -10 to +10 Vdc
External potentiometer
RX
RR
CC
PA/+
PB
PC/-
S/L2
T/L3
MCCB
or
ELCB