E6582062
6-91
6. [Advanced] How to use parameters
3
4
6
9
Due to residual voltage, auto-tuning may not be properly performed immediately after
running motor is stopped.
• There would be almost no rotation of the motor during offline auto-tuning, but you must keep
in mind that voltage is still applied during this time.
• During auto-offline tuning, "Atn" will be displayed on the LCD screen.
• Offline auto-tuning takes a few seconds. If any failure is found, tripping will occur with auto-
tuning error "Etn1" or "Etn2", and motor parameters will not be set.
• Offline auto-tuning cannot be performed on special motors. Calculate the motor parameters
using "Setting method 2".
• If offline auto-tuning cannot be performed or auto-tuning error "Etn1" or "Etn2" occurs, set
manually using "Setting method 3".
■
Setting method 2: Make auto-tuning of motor parameter after automatic setting.
Set PM motor control and then perform motor parameters auto calculation.
Check the motor name plate and set the following parameters first.
• <vL: Base frequency 1> (Rated frequency)
• <vLv: Base frequency voltage 1> (Rated voltage)
• <F405: Motor rated capacity>
• <F415: Motor rated current>
• <F417: Motor rated speed>
Next, set <Pt: V/f Pattern> to "6: PM motor control". For details of setting methods, refer to [5. 3. 4].
Then, select <F400> = "4: Motor parameters auto calculation (0 after execution)" and perform <vLv:
Base frequency voltage> auto calculation.
This setting can be made without connecting the motor since it only calculates.
After automatic setting of motor parameter with <F400> = "4", be sure to set <F400> to "2: Auto-
tuning at run command (0 after execution)" and execute an auto-tuning.
Since calculation is performed based on general trend, the calculation results may not be correct. In
this case, set the parameter manually.
■
Setting method 3: Manually setting motor parameter
Set <Pt: V/f Pattern> to "6: PM motor control" and set the motor parameter manually.
If tuning error "Etn1" is displayed during auto-tuning setting or when you want to improve PM motor
control characteristics, set motor parameters individually. For details of setting methods, refer to [5.
3. 4].
4) Parameter setting
Title
Parameter name
Adjustment range
Unit
Default setting
F402
Automatic torque boost
0.1 - 30.00
%
*1
F405
Motor rated capacity
0.01 - 315.0
kW
*1
F415
Motor rated current
*1
A
*1
*1
F417
Motor rated speed
100 - 64000
min
-1
*2
F459
Load inertia ratio
0.1 - 100.0
Times
1.0
F460
Speed control response
1
0.0 - 25.0
-
0.0
Summary of Contents for TOSVERT VF-AS3
Page 2: ...1 9 ...
Page 14: ......
Page 17: ...E6582062 iii I 3 9 15 Warranty 15 1 16 Disposal 16 1 ...
Page 18: ......
Page 34: ......
Page 438: ......
Page 458: ......
Page 470: ......
Page 482: ......
Page 502: ......
Page 572: ......
Page 590: ......
Page 608: ......
Page 616: ......
Page 618: ......
Page 620: ......
Page 621: ...1 3 9 10 ...