E6582062
6. [Advanced] How to use parameters
6-172
4
4
6
9
6. 34. 7 Holding display in [Standard mode]
<F709: Hold function of standard mode>
■
Function
The display in [Standard mode] can be held.
■
Parameter setting
■
Selecting a setting value
0: Real time
The contents selected with <F710: Standard mode display> are displayed.
1: Peak hold
2: Minimum hold
For peak hold values and minimum hold values, the maximum/minimum values in each operation
cycle are displayed.
• When the motor is at a standstill, the values monitored last are held as they were until the motor is
started the next time.
• The maximum and minimum values monitored after power is on are always displayed whether the
motor is running or at a standstill.
Title
Parameter name
Adjustment range
Default setting
F709
Hold function of standard
mode
0: Real time
1: Peak hold
2: Minimum hold
0
Reference
• How to operate the operation panel -> Refer to [3. 1. 1].
• How to switch display mode on the operation panel -> Refer to [3. 1. 2].
• Procedure to change parameter setting -> Refer to [4. 2. 3]
• Details on operation by external signals -> Refer to [Chapter 7].
1: Peak hold
2: Minimum hold
0.0Hz
STOP
14:13
0: Real time
F709 : Standard mode hold
Summary of Contents for TOSVERT VF-AS3
Page 2: ...1 9 ...
Page 14: ......
Page 17: ...E6582062 iii I 3 9 15 Warranty 15 1 16 Disposal 16 1 ...
Page 18: ......
Page 34: ......
Page 438: ......
Page 458: ......
Page 470: ......
Page 482: ......
Page 502: ......
Page 572: ......
Page 590: ......
Page 608: ......
Page 616: ......
Page 618: ......
Page 620: ......
Page 621: ...1 3 9 10 ...