E6582062
2. Installation and wiring
2-48
2
9
■
With frame size A3
VFAS3-2055P, 2075P, VFAS3-4110PC to 4185PC
1
Remove the front cover.
For how to remove, refer to [2. 2. 1].
2
Remove two screws for switching of grounding
capacitor.
The grounding capacitor is disconnected.
Insert the removed screws to the positions shown
in the figure on the right.
3
To recover the shipping state, mount the two
screws for switching of grounding capacitor and
tighten them.
The grounding capacitor is connected and
grounded.
4
After switching, mount the front cover.
For how to mount, refer to [2. 2. 1].
Important
• For models with two switching screws, be sure to set both screws to the same side.
Screw
Screw
Grounding
Non-grounding
Summary of Contents for TOSVERT VF-AS3
Page 2: ...1 9 ...
Page 14: ......
Page 17: ...E6582062 iii I 3 9 15 Warranty 15 1 16 Disposal 16 1 ...
Page 18: ......
Page 34: ......
Page 438: ......
Page 458: ......
Page 470: ......
Page 482: ......
Page 502: ......
Page 572: ......
Page 590: ......
Page 608: ......
Page 616: ......
Page 618: ......
Page 620: ......
Page 621: ...1 3 9 10 ...