E6582062
6. [Advanced] How to use parameters
6-110
4
4
6
9
6. 27. 2 Switching four types of acceleration/deceleration
<F500: Acceleration time 2>
<F501: Deceleration time 2>
<F503: Acc/Dec pattern 2>
<F504: Panel Acc/Dec select>
<F505: Acc/Dec switching frequency 1>
<F510: Acceleration time 3>
<F511: Deceleration time 3>
<F512: Acc/Dec pattern 3>
<F513: Acc/Dec switching frequency 2>
<F514: Acceleration time 4>
<F515: Deceleration time 4>
<F516: Acc/Dec pattern 4>
<F517: Acc/Dec switching frequency 3>
<F519: Unit of Acc/Dec time>
■
Function
You can set four types of options for each acceleration and deceleration time.
There are three setting methods to choose from four types.
1) Selection by the parameters
2) Switching by frequencies
3) Switching by the terminals
■
Setting of parameters
Title
Parameter name
Adjustment range
Unit
Default setting
ACC
Acceleration time 1
0.0 - 6000 (600.0)
s
*1
*1 Depending on capacity. For details, refer to [11. 6].
dEC
Deceleration time 1
0.0 - 6000 (600.0)
s
*1
F500
Acceleration time 2
0.0 - 6000 (600.0)
s
*1
F501
Deceleration time 2
0.0 - 6000 (600.0)
s
*1
F510
Acceleration time 3
0.0 - 6000 (600.0)
s
*1
F511
Deceleration time 3
0.0 - 6000 (600.0)
s
*1
F514
Acceleration time 4
0.0 - 6000 (600.0)
s
*1
F515
Deceleration time 4
0.0 - 6000 (600.0)
s
*1
F519
Unit of Acc/Dec time
0: -
1: 0.01 s unit (0 after execution)
2: 0.1 s unit (0 after execution)
-
0
0.0Hz
STOP
13:50
F500 : Acceleration time 2
Min: 0.0
Max: 6000.0
X1000
X100
X10
X1
10.0
s
1: 0.01s unit (0 after execution)
2: 0.01s unit (1 after execution)
0.0Hz
STOP
13:51
0: -
F519 : Unit of Acc/Dec time
Summary of Contents for TOSVERT VF-AS3
Page 2: ...1 9 ...
Page 14: ......
Page 17: ...E6582062 iii I 3 9 15 Warranty 15 1 16 Disposal 16 1 ...
Page 18: ......
Page 34: ......
Page 438: ......
Page 458: ......
Page 470: ......
Page 482: ......
Page 502: ......
Page 572: ......
Page 590: ......
Page 608: ......
Page 616: ......
Page 618: ......
Page 620: ......
Page 621: ...1 3 9 10 ...