Selecting an overload protection characteristic
<AUL: Multi-rating select>
■
Function
Select an inverter overload protection characteristic suited for the torque characteristic of the
machine.
■
Parameter setting
Note) The setting value becomes 0 after execution, but a check mark is added to the previous
setting value.
■
Selecting a setting value
2: ND rating (120%-60s) (0 after execution)
Select this value when applying the machine with variable torque characteristic.
Example) Fan, pump, blower, etc.
3: HD rating (150%-60s) (0 after execution)
Select this value when applying the machine with constant torque characteristics.
Example) Conveyor, load transporting machinery, crane, concrete mixer, compressor, making
machine, machine tool, etc.
Title
Parameter name
Adjustment range
Default
setting
AUL
Multi-rating select
0,1: -
2: ND rating (120%-60s) (0 after execution)
3: HD rating (150%-60s) (0 after execution)
4 - 8: -
3
Memo
• The default setting of some parameters are different between HD rating and ND rating. Refer to
0.0Hz
STOP
15:22
AUL : Multi-rating select
0: -
1: -
2: ND rating (120%-60s)(0 after set)
3: HD rating (150%-60s)(0 after set)
4: -
Basic parameter
Summary of Contents for TOSVERT VF-AS3
Page 2: ...1 9 ...
Page 14: ......
Page 17: ...E6582062 iii I 3 9 15 Warranty 15 1 16 Disposal 16 1 ...
Page 18: ......
Page 34: ......
Page 438: ......
Page 458: ......
Page 470: ......
Page 482: ......
Page 502: ......
Page 572: ......
Page 590: ......
Page 608: ......
Page 616: ......
Page 618: ......
Page 620: ......
Page 621: ...1 3 9 10 ...