RELEASE 2.X UPGRADE INSTRUCTIONS
13-19
Edition One
XC1000 Service
Menu 6 – Dialing and Serial Channel Parameters
1 – Transfer, Outcall, and Pager Dialing Sequences
2 – In–band Integration Dialing Sequences
3 – Define CPU Serial Channel
4 – MTA (Multiple Terminal Access) Parameters
5 – Integration Link Management
Enter Option:
Figure 13-14. Menu 6 – Dialing and Serial
Channel Parameters.
13.14.1 Define CPU Serial Channels in Menu 6.3
XC1000 has external, physical connectors on the main distribution board,
five of which connect internally to four CPU ports. Channel 4 is used for
service and for the primary SMT. Channels 1, 2, and 3 can be configured
for system management or for integration. Table 13-1 shows CPU channels
as they relate to the physical connectors.
The primary SMT port is a data-circuit-terminating-equipment (DCE)
connector. Because J43, J44, and J46 are data-terminal-equipment (DTE)
connectors, a null-modem adapter must be used with the connectors. Any
of these connectors can be used, but the XC1000 can only support one
primary SMT and two secondary SMTs.
Table 13-1. XC1000 CPU Serial Channels
and Physical Connectors.
1
J44 Integration/SMT
2
J43
Integration/SMT
3 J46
Integration/SMT
4
J50
Service/Primary SMT
a
J45
Service/Primary SMT
b
–
RDAC
Remote Diagnostic Access
a
Monitor card installed.
b
No monitor card installed.
Channel
Physical
Function
Connector
Number
To configure ports on the XC1000 main distribution board as secondary
system-manager terminals or as direct RS-232 integrations, select option
3
from menu 6 and press the
Enter
key. Menu 6.3 appears, similar to
Figure 12-14. The following sections explain how to configure CPU serial
channels.
SECTION 13.14
Summary of Contents for XC1000
Page 1: ...EDITION ONE XC1000 P N 101 1345 000 SERVICE MANUAL ...
Page 8: ...CONTENTS ...
Page 19: ...1 INTRODUCTION ...
Page 30: ...2 SITE PREPARATION ...
Page 60: ...3 PLATFORM INSTALLATION ...
Page 112: ...4 STARTUP AND INITIALIZATION ...
Page 177: ...5 ROUTINE MAINTENANCE ...
Page 195: ...6 TROUBLESHOOTING ...
Page 237: ...7 STATUS LOG ...
Page 297: ...STATUS LOG 7 54 Edition One XC1000 Service ...
Page 302: ...8 REPAIR AND REPLACEMENT ...
Page 380: ...9 SYSTEM UTILITIES ...
Page 424: ...10 COMPONENT DESCRIPTIONS ...
Page 465: ...11 OPTIONAL FEATURES ...
Page 485: ...12 RELEASE 1 55 UPGRADE INSTRUCTIONS ...
Page 516: ...13 RELEASE 2 X UPGRADE INSTRUCTIONS ...
Page 559: ...14 RELEASE 3 02 FCP CONVERSION INSTRUCTIONS ...
Page 603: ...15 RELEASE 3 02 ONLINE UPGRADE INSTRUCTIONS ...
Page 631: ...16 RELEASE 3 0 SYSTEM UTILITIES ...
Page 683: ...17 RELEASE 4 X FCP CONVERSION INSTRUCTIONS r P N 281 0023 002 1 of 3 ...
Page 725: ...18 RELEASE 4 X ONLINE UPGRADE INSTRUCTIONS r P N 281 0023 002 2 of 3 ...
Page 760: ...19 RELEASE 4 0 SYSTEM UTILITIES P N 281 0023 002 Part 3 of 3 r ...
Page 776: ...20 RELEASE 4 1 SYSTEM UTILITIES P N 281 0033 000 ...
Page 787: ...APPENDIXES ...