RELEASE 4.X FCP CONVERSION INSTRUCTIONS
17-34
Release 4.X
XC1000 Service
41. Press
Enter
. The XC1000 automatically reboots.
42. At the blank screen, press
Enter
again. The
Please Enter System
Manager Password:
prompt appears.
43. Enter the system-manager password and press
Enter
. The SMT Main
Menu appears.
44. If the CPU card has been replaced, select option
3
to check date and
time for your time zone.
45. From the SMT Main Menu, select option 4. Reset port parameters to
Y
, as shown in the port configuration report printed before the FCP
conversion was started (section 17.4). Press
F11
to save the input.
46. At
Port assignments updated. Press any key to continue.
, press
Enter
repeatedly until the SMT Main Menu is displayed.
47. If desired, review menus 13.2, 13.4, and 13.7 to verify the new
software level. The XC1000 should now be running successfully on
Release 4.X software.
48. Disconnect the PC from the XC1000 and reconnect the SMT.
17.10 DISABLE THE ENGINEERING BIT
Call the Octel TAC to have the engineering bit turned off.
17.11 PURGE AND CONVERT FOLLOW-ME-FORWARD
MAILBOXES
If the XC1000 is a standalone, non-networked XC1000, skip this section.
If the XC1000 is part of a network, perform the purge and convert follow-
me-forward mailbox-conversion procedure on all voice processors in the
network every time a new voice processor is added to the network.
Refer to the
Release 4.0 System Manager Manual
, Addendum III for
instructions on how to purge and convert follow-me-forward mailboxes.
17.12 FCP CONVERSION STAGES
The FCP conversion is divided into numbered stages, starting with the
number 10. All of the stages are described in this section. Gaps in the
numbering do not indicate missing stages.
As the FCP conversion is performed, messages appear on the screen. Some
of these messages are for information only; others require a response.
Do not press any keys unless prompted to do so. Pressing a key when the
conversion PC is expecting a response from the XC1000 might cause the
procedure to fail.
If the PC screen-saver program is activated during the conversion, press
only the
Shift
key to redisplay the screen.
SECTION 17.9 – 17.12
Summary of Contents for XC1000
Page 1: ...EDITION ONE XC1000 P N 101 1345 000 SERVICE MANUAL ...
Page 8: ...CONTENTS ...
Page 19: ...1 INTRODUCTION ...
Page 30: ...2 SITE PREPARATION ...
Page 60: ...3 PLATFORM INSTALLATION ...
Page 112: ...4 STARTUP AND INITIALIZATION ...
Page 177: ...5 ROUTINE MAINTENANCE ...
Page 195: ...6 TROUBLESHOOTING ...
Page 237: ...7 STATUS LOG ...
Page 297: ...STATUS LOG 7 54 Edition One XC1000 Service ...
Page 302: ...8 REPAIR AND REPLACEMENT ...
Page 380: ...9 SYSTEM UTILITIES ...
Page 424: ...10 COMPONENT DESCRIPTIONS ...
Page 465: ...11 OPTIONAL FEATURES ...
Page 485: ...12 RELEASE 1 55 UPGRADE INSTRUCTIONS ...
Page 516: ...13 RELEASE 2 X UPGRADE INSTRUCTIONS ...
Page 559: ...14 RELEASE 3 02 FCP CONVERSION INSTRUCTIONS ...
Page 603: ...15 RELEASE 3 02 ONLINE UPGRADE INSTRUCTIONS ...
Page 631: ...16 RELEASE 3 0 SYSTEM UTILITIES ...
Page 683: ...17 RELEASE 4 X FCP CONVERSION INSTRUCTIONS r P N 281 0023 002 1 of 3 ...
Page 725: ...18 RELEASE 4 X ONLINE UPGRADE INSTRUCTIONS r P N 281 0023 002 2 of 3 ...
Page 760: ...19 RELEASE 4 0 SYSTEM UTILITIES P N 281 0023 002 Part 3 of 3 r ...
Page 776: ...20 RELEASE 4 1 SYSTEM UTILITIES P N 281 0033 000 ...
Page 787: ...APPENDIXES ...