STATUS LOG
7-13
Edition One
XC1000 Service
Interpret these status codes as follows:
1. Refer to Table 7-4, the
Bank:Slot Address
column, or Figure 7-4, for
the possible bank:slot values for offset 07.
2. If any of status-codes 50 through 58 keep reporting the same card in
offset 07, replace the card. Refer to section 8.3.1 for the procedure to
replace a logic card. Refer to section 8.3.2.1 to replace a TIC or DLC.
3. If the entries repeat but do not always report the same card in offset
07, replace the CPU (section 8.3.1).
7.3.7 Status-Code 60
A status-code 60 provides the status of the logic cards installed in XC1000.
When a status-code 60 is logged, perform the following steps:
1. Check the contents of the subcode in offsets 08 and 09, as listed in
Table 7-7.
Table 7-7. Subcode Values in Offsets 08, 09
for Status Code 60.
Description
00
Inactive logic card was detected.
01
Logic card uploaded and running.
03
Logic-card diagnostic test failed.
04
Logic card failed to upload.
05
No DLC was found in system.
Subcode
Value
2. Depending on the value found in offsets 08 and 09, also check offset
07 to determine additional information about the log entry.
Offset 07 shows the physical card-slot number, in hexadecimal, with
which the CPU was communicating through the CB message. For
example, if the value in offset 07 is
16
, the physical slot number
would be 22 (in decimal), which is CPU B in a standby-redundant
XC1000.
Figure 7-12 is an example of a status-code 60 entry with the pertinent
offsets and detail highlighted.
20 OCT 92 05:49:31PM
*** Logic Card Error
>>> NOTIFY SUPPORT REPRESENTATIVE
00000
10009E00
60000003
00001F6D
51450100
Figure 7-12. Example of Status-Code 60.
SECTION 7.3
Summary of Contents for XC1000
Page 1: ...EDITION ONE XC1000 P N 101 1345 000 SERVICE MANUAL ...
Page 8: ...CONTENTS ...
Page 19: ...1 INTRODUCTION ...
Page 30: ...2 SITE PREPARATION ...
Page 60: ...3 PLATFORM INSTALLATION ...
Page 112: ...4 STARTUP AND INITIALIZATION ...
Page 177: ...5 ROUTINE MAINTENANCE ...
Page 195: ...6 TROUBLESHOOTING ...
Page 237: ...7 STATUS LOG ...
Page 297: ...STATUS LOG 7 54 Edition One XC1000 Service ...
Page 302: ...8 REPAIR AND REPLACEMENT ...
Page 380: ...9 SYSTEM UTILITIES ...
Page 424: ...10 COMPONENT DESCRIPTIONS ...
Page 465: ...11 OPTIONAL FEATURES ...
Page 485: ...12 RELEASE 1 55 UPGRADE INSTRUCTIONS ...
Page 516: ...13 RELEASE 2 X UPGRADE INSTRUCTIONS ...
Page 559: ...14 RELEASE 3 02 FCP CONVERSION INSTRUCTIONS ...
Page 603: ...15 RELEASE 3 02 ONLINE UPGRADE INSTRUCTIONS ...
Page 631: ...16 RELEASE 3 0 SYSTEM UTILITIES ...
Page 683: ...17 RELEASE 4 X FCP CONVERSION INSTRUCTIONS r P N 281 0023 002 1 of 3 ...
Page 725: ...18 RELEASE 4 X ONLINE UPGRADE INSTRUCTIONS r P N 281 0023 002 2 of 3 ...
Page 760: ...19 RELEASE 4 0 SYSTEM UTILITIES P N 281 0023 002 Part 3 of 3 r ...
Page 776: ...20 RELEASE 4 1 SYSTEM UTILITIES P N 281 0033 000 ...
Page 787: ...APPENDIXES ...