RELEASE 3.02 ONLINE UPGRADE INSTRUCTIONS
15-5
Edition One
XC1000 Service
If the SMT baud rate is unknown, perform the following steps:
1. From the SMT Main Menu prompt, type
6
, then press the
Return
key to access Menu 6 – Dialing Parameters
.
2. Type
3
, then press the
Return
key to access menu 3 – Define CPU
Serial Channel. Review the baud rate information for the port to
which the SMT is connected.
3. Keep track of the current SMT baud rate for the XC1000 being
upgraded.
4. Press
^C
twice to return to the SMT Main Menu without making
changes.
15.6 VERIFY THE SYSTEM BOOT AREA
Perform the following steps to verify the system boot area:
1. From the SMT Main Menu prompt, type
20
, then press the
Return
key to access Menu 20 – Service Operations.
2. Select the
Miscellaneous Utilities
option by typing the associated
menu number. Then press the
Return
key.
3. Select the
Set System Boot Area
option by typing the associated
menu number. Then press the
Return
key.
4. The current
System Boot Area:
and
Drive Next Boot Area:
fields are
displayed, showing software versions of the current
System Boot
Area:
field.
5. Verify that the current
System Boot Area:
and
Drive Next Boot
Area:
fields are redundant by performing the following procedure:
If the boot areas are the same, press
^C
three times to return to
the SMT Main Menu without changing anything.
If the boot areas are not redundant, at the
Enter area (A or B):
prompt, enter either
A
or
B
, then press the
Return
key to make
the areas redundant.
At the
Set Boot Area Complete...Press any key to continue
prompt, press
^C
three times to return to the SMT Main Menu.
15.7 CONNECT THE PC AND THE XC1000
Place the PC next to the XC1000, and perform the following steps to
connect the PC and the XC1000.
1. With the XC1000 on line, disconnect the SMT cable, P/N
057–1174–000, from the back of the terminal. Set aside the terminal.
2. Plug the disconnected end of the adapter into a female/female
DB25/DB9 gender changer adapter, P/N 003–1091–000.
If the PC COM port has a 25-pin male connection, use a female/
female DB25/DB25 gender changer adapter, P/N 003–1092–000.
SECTION 15.5 – 15.7
Summary of Contents for XC1000
Page 1: ...EDITION ONE XC1000 P N 101 1345 000 SERVICE MANUAL ...
Page 8: ...CONTENTS ...
Page 19: ...1 INTRODUCTION ...
Page 30: ...2 SITE PREPARATION ...
Page 60: ...3 PLATFORM INSTALLATION ...
Page 112: ...4 STARTUP AND INITIALIZATION ...
Page 177: ...5 ROUTINE MAINTENANCE ...
Page 195: ...6 TROUBLESHOOTING ...
Page 237: ...7 STATUS LOG ...
Page 297: ...STATUS LOG 7 54 Edition One XC1000 Service ...
Page 302: ...8 REPAIR AND REPLACEMENT ...
Page 380: ...9 SYSTEM UTILITIES ...
Page 424: ...10 COMPONENT DESCRIPTIONS ...
Page 465: ...11 OPTIONAL FEATURES ...
Page 485: ...12 RELEASE 1 55 UPGRADE INSTRUCTIONS ...
Page 516: ...13 RELEASE 2 X UPGRADE INSTRUCTIONS ...
Page 559: ...14 RELEASE 3 02 FCP CONVERSION INSTRUCTIONS ...
Page 603: ...15 RELEASE 3 02 ONLINE UPGRADE INSTRUCTIONS ...
Page 631: ...16 RELEASE 3 0 SYSTEM UTILITIES ...
Page 683: ...17 RELEASE 4 X FCP CONVERSION INSTRUCTIONS r P N 281 0023 002 1 of 3 ...
Page 725: ...18 RELEASE 4 X ONLINE UPGRADE INSTRUCTIONS r P N 281 0023 002 2 of 3 ...
Page 760: ...19 RELEASE 4 0 SYSTEM UTILITIES P N 281 0023 002 Part 3 of 3 r ...
Page 776: ...20 RELEASE 4 1 SYSTEM UTILITIES P N 281 0033 000 ...
Page 787: ...APPENDIXES ...