SYSTEM UTILITIES
9-33
Edition One
XC1000 Service
Do not run garbage collect with the master drive installed.
If garbage collect is run with the master drive in system-
drive-slot 0 (S0), all messages will be lost.
Caution!
Perform the following steps to run garbage collect:
1. Coordinate with the system manager before taking the XC1000 out of
service.
2. Disable all multiline hunt groups and SMDI links going to the XC1000
by using one of the following methods:
Divert the pilot number of the multiline hunt group.
Remove the Amphenol connectors from the SMDI connections on
the main backplane.
Disable all line tasks in menu 4.
3. Type
^C
twice to return to the SMT Main Menu.
4. If a data module is connected to the XC1000, the X.25 link must be
stopped before running garbage collect. From the Main Menu, select
option
18
for X.25 Interface Management.
5. From menu 18, select option
3
for X.25 Interface Operation. Menu
18.3 appears, as shown in Figure 9-11.
Menu 18 – X.25 Interface Management
– Interface Operation –
Physical Interface Number: 0
Enter “1” – Start, “2” – Immediate Stop:
Enter the number of the operation you wish to perform.
Press “Break” to enter a new Physical Interface Number.
Interface
Status
–––––––––
––––––
0
PHYSICAL (L1) STARTED
Figure 9-11. Menu 18.3, Interface Operation.
6. In the
Physical Interface Number:
field, enter the number of the
XC1000 DB25 connector to which the X.25 link is connected and
press the
Enter
key. Valid interface numbers are
0
and
1
.
7. In response to the prompts at the bottom of the screen in menu 18.3,
type
2
for Immediate Stop and press the
Enter
key. Press
^C
or the
Break
key until the Main Menu reappears.
SECTION 9.7
Summary of Contents for XC1000
Page 1: ...EDITION ONE XC1000 P N 101 1345 000 SERVICE MANUAL ...
Page 8: ...CONTENTS ...
Page 19: ...1 INTRODUCTION ...
Page 30: ...2 SITE PREPARATION ...
Page 60: ...3 PLATFORM INSTALLATION ...
Page 112: ...4 STARTUP AND INITIALIZATION ...
Page 177: ...5 ROUTINE MAINTENANCE ...
Page 195: ...6 TROUBLESHOOTING ...
Page 237: ...7 STATUS LOG ...
Page 297: ...STATUS LOG 7 54 Edition One XC1000 Service ...
Page 302: ...8 REPAIR AND REPLACEMENT ...
Page 380: ...9 SYSTEM UTILITIES ...
Page 424: ...10 COMPONENT DESCRIPTIONS ...
Page 465: ...11 OPTIONAL FEATURES ...
Page 485: ...12 RELEASE 1 55 UPGRADE INSTRUCTIONS ...
Page 516: ...13 RELEASE 2 X UPGRADE INSTRUCTIONS ...
Page 559: ...14 RELEASE 3 02 FCP CONVERSION INSTRUCTIONS ...
Page 603: ...15 RELEASE 3 02 ONLINE UPGRADE INSTRUCTIONS ...
Page 631: ...16 RELEASE 3 0 SYSTEM UTILITIES ...
Page 683: ...17 RELEASE 4 X FCP CONVERSION INSTRUCTIONS r P N 281 0023 002 1 of 3 ...
Page 725: ...18 RELEASE 4 X ONLINE UPGRADE INSTRUCTIONS r P N 281 0023 002 2 of 3 ...
Page 760: ...19 RELEASE 4 0 SYSTEM UTILITIES P N 281 0023 002 Part 3 of 3 r ...
Page 776: ...20 RELEASE 4 1 SYSTEM UTILITIES P N 281 0033 000 ...
Page 787: ...APPENDIXES ...