![Octel XC1000 Service Manual Download Page 66](http://html.mh-extra.com/html/octel/xc1000/xc1000_service-manual_723818066.webp)
PLATFORM INSTALLATION
3-2
Edition One
XC1000 Service
3.2.1 Electrical Safety
Before connecting the –48 Vdc primary-power leads to the XC1000, take
the following precautions:
-
Make sure that the –48 Vdc branch circuit breaker is off or fuses are
removed, as applicable.
-
Always connect the ground leads before the live leads.
-
Make sure to check the equipment ground connection to the building
(earth) ground.
For the safety of personnel, when working on the XC1000,
always
wear an antistatic wrist strap that is grounded to
the XC1000 cabinet and that contains a minimum of 1
megohm resistance from attachment to wrist. Handle cards
only by their sheet-metal stiffeners. Do not touch the
components or the edge connectors. Do not stack the cards
on top of one another. All circuit cards in the XC1000 can be
damaged by static discharge currents or by physical
mishandling.
Caution!
Some of the installation tasks require attaching cables to the XC1000,
grounding the XC1000, installing modules, and setting configuration
switches on telephone interface cards (TICs). When performing any of
these tasks, follow these precautions:
-
Because the XC1000 modules are sensitive to static, when working on
the XC1000, make sure to wear an antistatic wrist strap that is
grounded to the XC1000 cabinet and that contains a minimum of 1
megohm resistance from attachment to wrist.
-
Be careful when handling cards; do not touch either the components
or the edge connectors.
-
Do not stack the cards on top of one another.
Keep modules that are not installed in the XC1000 in their
antistatic bags (modules are shipped in such bags). Make
sure that modules are packaged in antistatic bags if
returned to the factory.
Caution!
-
Always
keep modules that are not installed in the XC1000 in their
antistatic bags in which they are shipped. If modules must be
returned to the factory, make sure to package them in antistatic bags.
SECTION 3.2
Summary of Contents for XC1000
Page 1: ...EDITION ONE XC1000 P N 101 1345 000 SERVICE MANUAL ...
Page 8: ...CONTENTS ...
Page 19: ...1 INTRODUCTION ...
Page 30: ...2 SITE PREPARATION ...
Page 60: ...3 PLATFORM INSTALLATION ...
Page 112: ...4 STARTUP AND INITIALIZATION ...
Page 177: ...5 ROUTINE MAINTENANCE ...
Page 195: ...6 TROUBLESHOOTING ...
Page 237: ...7 STATUS LOG ...
Page 297: ...STATUS LOG 7 54 Edition One XC1000 Service ...
Page 302: ...8 REPAIR AND REPLACEMENT ...
Page 380: ...9 SYSTEM UTILITIES ...
Page 424: ...10 COMPONENT DESCRIPTIONS ...
Page 465: ...11 OPTIONAL FEATURES ...
Page 485: ...12 RELEASE 1 55 UPGRADE INSTRUCTIONS ...
Page 516: ...13 RELEASE 2 X UPGRADE INSTRUCTIONS ...
Page 559: ...14 RELEASE 3 02 FCP CONVERSION INSTRUCTIONS ...
Page 603: ...15 RELEASE 3 02 ONLINE UPGRADE INSTRUCTIONS ...
Page 631: ...16 RELEASE 3 0 SYSTEM UTILITIES ...
Page 683: ...17 RELEASE 4 X FCP CONVERSION INSTRUCTIONS r P N 281 0023 002 1 of 3 ...
Page 725: ...18 RELEASE 4 X ONLINE UPGRADE INSTRUCTIONS r P N 281 0023 002 2 of 3 ...
Page 760: ...19 RELEASE 4 0 SYSTEM UTILITIES P N 281 0023 002 Part 3 of 3 r ...
Page 776: ...20 RELEASE 4 1 SYSTEM UTILITIES P N 281 0033 000 ...
Page 787: ...APPENDIXES ...