RELEASE 1.55 UPGRADE INSTRUCTIONS
12-23
Edition One
XC1000 Service
7. In the
Number of Data Bits:
field, enter one of the following:
0
– seven data bits
1
– eight data bits
8. In the
Number of Stop Bits:
field, enter one of the following:
0
– one stop bit
1
– two stop bits
9. In the
Parity (Odd/Even):
field, enter one of the following:
0
– no parity
1
–
odd parity
2
– even parity
10. In the
Data Carrier Detect? (Y/N):
field, enter
Y
or
N.
11. In the
Broadcast to this Channel for Dump/IPL? (Y/N)
: field, enter
Y
or
N.
12. In the fields listed under
Menu Access Allowed this Terminal
enter
a
Y
in the fields to which this terminal has access. Enter an
N
in the
fields that the terminal cannot access. These fields can also be
changed for a PC-based MTA.
Repeat these steps for all ACP-based MTA channels. Select option
4
,
suboption
2
, in menu 6 to review a summary of the entries created in the
previous menu. For more information about MTA installation, refer to the
MTA Installation Instruction 181–1036–001 for 286 PCs or Installation
Instruction 181–1036–002 for 386 PCs.
12.10.3 Manage Integration Links in Menu 6.5
Use menu 6.5 to configure integration links connected to the RS-232 ports
on the distribution board or to the ACP I/O distribution boards. After the
links are added in menu 6.5.1, they are managed by using the remaining
submenus of menu 6.5, including changing link configuration, reviewing an
integration link, deleting an integration link, resetting an integration link,
and viewing the status of an integration link.
If an SMDI integration is currently connected to connector J44, J43, or
J46, it must be configured in menus 6.3 and 6.5. From menu 6
(Figure 12-13), select option
5
for Integration Link Management.
Figure 12-16 shows menu 6.5.
12.10.3.1 Add an Integration Link.
To add an integration link, perform the following
steps:
1. From menu 6.5, select option 1. Menu 6.5.1 appears, with only the
Link Number:
field displayed.
2. In the
Link Number:
field, add a link number associated with the link
connections on the distribution board or ACP I/O distribution boards.
Valid entries are
1
through
16
.
The
Link Name:
field and the
Type of Switch to which the System
is Integrated:
field appear after entering a link number.
SECTION 12.10
Summary of Contents for XC1000
Page 1: ...EDITION ONE XC1000 P N 101 1345 000 SERVICE MANUAL ...
Page 8: ...CONTENTS ...
Page 19: ...1 INTRODUCTION ...
Page 30: ...2 SITE PREPARATION ...
Page 60: ...3 PLATFORM INSTALLATION ...
Page 112: ...4 STARTUP AND INITIALIZATION ...
Page 177: ...5 ROUTINE MAINTENANCE ...
Page 195: ...6 TROUBLESHOOTING ...
Page 237: ...7 STATUS LOG ...
Page 297: ...STATUS LOG 7 54 Edition One XC1000 Service ...
Page 302: ...8 REPAIR AND REPLACEMENT ...
Page 380: ...9 SYSTEM UTILITIES ...
Page 424: ...10 COMPONENT DESCRIPTIONS ...
Page 465: ...11 OPTIONAL FEATURES ...
Page 485: ...12 RELEASE 1 55 UPGRADE INSTRUCTIONS ...
Page 516: ...13 RELEASE 2 X UPGRADE INSTRUCTIONS ...
Page 559: ...14 RELEASE 3 02 FCP CONVERSION INSTRUCTIONS ...
Page 603: ...15 RELEASE 3 02 ONLINE UPGRADE INSTRUCTIONS ...
Page 631: ...16 RELEASE 3 0 SYSTEM UTILITIES ...
Page 683: ...17 RELEASE 4 X FCP CONVERSION INSTRUCTIONS r P N 281 0023 002 1 of 3 ...
Page 725: ...18 RELEASE 4 X ONLINE UPGRADE INSTRUCTIONS r P N 281 0023 002 2 of 3 ...
Page 760: ...19 RELEASE 4 0 SYSTEM UTILITIES P N 281 0023 002 Part 3 of 3 r ...
Page 776: ...20 RELEASE 4 1 SYSTEM UTILITIES P N 281 0033 000 ...
Page 787: ...APPENDIXES ...